OPERATION
screw fully clockwise and then energize and
11. Replace the filter section access panel.
COOLING SYSTEM
The unit has an
The compressor is hermetically sealed, internally sprung, mounted on spring isolators and inherently (internally) protected. If there is an abnormal temperature rise in the compressor, the protector opens to shut down the compressor.
PRELIMINARY OPERATION COOLING
MINUTES | 250 |
|
|
|
|
|
|
| |
200 |
| T3 - 110 Minute Setting (Factory Set Point) |
| ||||||
CYCLES, |
|
|
| ||||||
150 |
|
|
| T2 - 80 Minute Setting |
| ||||
|
|
|
|
| |||||
DEFROST |
|
|
|
|
| ||||
100 |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
BETWEEN | 50 |
|
|
|
|
|
|
| |
|
|
| T1 - 50 Minute Setting |
|
|
| |||
TIME |
|
|
|
|
|
| |||
0 |
|
|
|
|
|
|
| ||
0 | 10 | 20 | 30 | 40 | 50 | 60 | |||
| |||||||||
|
|
| OUTDOOR AMBIENT, DEG. F |
|
|
After the installation has been completed, the crankcase heater of the compressor must be energized for at least 4 hours before starting the unit. After this initial
NOTE: Prior to each cooling season, the crankcase heater must be energized at least 10 hours before the system is put into operation.
COOLING SEQUENCE OF OPERATION
When the thermostat calls for cooling, the compressor and the outdoor fan motor will be energized through terminal “Y1" and the supply air blower motor will be energized through terminal ”G" (if the fan switch on the subbase is set in the “AUTO” position). The supply air blower motor will run continuously if the fan switch is set in the “ON” position.
The reversing valve is energized thru the “O” circuit when the subbase is in the cooling mode.
HEATING SEQUENCE OF OPERATION
The following sequence of operation is based on using a standard YORK heat pump thermostat with two heating stages.
FIRST STAGE HEAT
When the thermostat calls for heating, the compressor and the outdoor fan motor will be energized through terminal “Y1" and the supply air blower motor will be energized through terminal ”G" (if the fan switch on the subbase is set in the “AUTO” position). The supply air blower motor will run continuously if the fan switch is set in the “ON” position.
SECOND STAGE HEAT
If compressor operation can not satisfy the heating requirements, second stage heat will energize supplemental electric heat (if supplied) thru the “W1" circuit.
DEFROST SEQUENCE OF OPERATION
The BCH has a unique “ambient modified”
FIG. 7 - DEFROST INITIATION TIMES
adjusted to defrost at 80 minutes (T2) or 50 minutes (T1) in areas with high humidity.
The curve in Figure 7 shows how defrost initiation times are automatically compensated for changes in outdoor temperature.
EXAMPLE: If the time is factory set on pin
If the outdoor temperature drops to
Two requirements must be met before a defrost cycle can be initiated.
1.The defrost time cycle must be complete.
2.The liquid line temperature must be less than
Defrost terminates when the liquid line sensor reaches 13°C (55°F) or after 10 minutes.
The defrost time cycle restarts 10 minutes after the start of the defrost cycle even though the liquid sensor terminated defrost after 3 minutes.
T2 - 80 MINUTE SETTING |
|
T3 - 110 MINUTE SETTING |
|
(Factory Set Point) | T1 - 50 MINUTE SETTING |
SHORTING PEGS TO
OVERRIDE TIMER
FOR SERVICE
MOVABLE JUMPER
WIRE TO CHANGE
DEFROST TIMER
FIG. 8 - AMBIENT MODIFIED TIME/TEMPERATURE CONTROL