246695-YTG-C-0708

TABLE 5: DJ 150 (12 1/2 TON) COOLING CAPACITY

Air On

 

Temperature of Air on Condenser Coil 85°F

 

 

Temperature of Air on Condenser Coil 95°F

 

Evap. Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WB

Tot.

 

Tot.

 

Sensible Capacity (MBH)1

 

Tot.

 

Tot.

 

Sensible Capacity (MBH)1

 

CFM

Cap.1

 

Input2

 

Return Dry Bulb (°F)

 

Cap.1

 

Input2

 

Return Dry Bulb (°F)

 

(°F)

 

 

 

 

 

 

 

(MBH)

 

(kW)

86

83

80

77

74

71

68

(MBH)

 

(kW)

86

83

80

77

74

71

68

 

 

 

 

 

72

173

 

10.9

102

92

81

70

60

49

38

168

 

11.8

101

90

79

69

58

47

37

3750

67

160

 

10.6

127

116

105

95

84

73

63

154

 

11.6

124

114

103

92

81

71

60

62

148

 

10.5

148

141

131

120

109

99

88

143

 

11.4

143

138

127

116

106

95

84

 

 

 

 

57

147

 

10.5

147

144

133

123

112

101

91

141

 

11.5

141

137

126

116

105

94

84

 

72

177

 

10.9

112

100

87

74

62

49

37

170

 

11.8

111

98

85

73

60

47

35

4375

67

163

 

10.7

138

126

113

101

88

75

63

156

 

11.7

136

123

110

98

85

72

60

62

151

 

10.6

151

148

141

128

115

103

90

145

 

11.5

145

142

136

124

111

98

86

 

 

 

 

57

150

 

10.5

150

149

143

131

118

106

93

143

 

11.5

143

141

136

123

110

98

85

 

72

180

 

11.0

122

108

93

79

64

49

35

173

 

11.9

120

106

91

76

62

47

33

5000

67

167

 

10.7

150

136

121

107

92

77

63

158

 

11.8

147

132

118

103

89

74

60

62

154

 

10.6

154

154

150

136

121

107

92

147

 

11.6

147

147

146

131

116

102

87

 

 

 

 

57

154

 

10.6

154

154

154

139

124

110

95

145

 

11.6

145

145

145

130

116

101

87

 

72

184

 

11.0

133

116

100

83

66

50

33

176

 

12.0

131

114

98

81

65

48

31

5625

67

170

 

10.8

162

146

129

113

96

80

63

161

 

11.8

155

143

127

110

93

77

60

62

157

 

10.7

157

157

155

139

122

106

89

150

 

11.7

150

150

149

132

116

99

83

 

 

 

 

57

157

 

10.6

157

157

157

140

123

107

90

147

 

11.7

147

147

147

131

114

98

81

 

72

188

 

11.1

143

125

106

87

69

50

32

179

 

12.1

142

123

105

86

67

49

30

6250

67

173

 

10.8

173

156

138

119

101

82

63

164

 

11.9

164

154

135

117

98

79

61

62

161

 

10.7

161

161

161

142

123

105

86

152

 

11.7

152

152

152

134

115

96

78

 

 

 

 

57

160

 

10.6

160

160

160

141

122

104

85

150

 

11.8

150

150

150

131

113

94

75

 

 

 

 

Temperature

of

Air on

Condenser Coil 105°F

 

 

 

Temperature of Air on Condenser Coil 115°F

 

 

72

158

 

13.0

99

88

77

67

56

45

34

148

 

14.3

96

86

75

64

54

43

32

3750

67

145

 

12.9

120

110

99

88

78

67

56

136

 

14.2

116

106

95

84

74

63

52

62

134

 

12.7

134

129

119

108

97

87

76

125

 

14.0

125

121

110

100

89

78

67

 

 

 

 

57

134

 

12.8

134

130

119

109

98

87

77

128

 

14.2

128

123

112

102

91

80

70

 

72

160

 

13.1

109

96

83

71

58

45

33

150

 

14.4

107

94

81

69

56

43

31

4375

67

147

 

13.0

132

119

107

94

81

69

56

138

 

14.2

128

116

103

90

78

65

52

62

136

 

12.8

136

134

128

115

103

90

77

127

 

14.1

127

125

120

107

94

82

69

 

 

 

 

57

136

 

12.9

136

134

129

116

103

91

78

130

 

14.2

130

127

122

109

97

84

71

 

72

162

 

13.2

119

104

89

75

60

46

31

152

 

14.4

117

102

88

73

58

44

29

5000

67

149

 

13.0

144

129

114

100

85

71

56

140

 

14.3

140

126

111

96

82

67

53

62

138

 

12.8

138

138

137

123

108

93

79

129

 

14.1

129

129

129

114

100

85

70

 

 

 

 

57

138

 

12.9

138

138

138

124

109

94

80

131

 

14.3

131

131

131

117

102

88

73

 

72

165

 

13.2

129

112

96

79

63

46

29

155

 

14.5

127

111

94

77

61

44

28

5625

67

152

 

13.1

149

139

123

106

90

73

56

143

 

14.3

143

135

119

102

86

69

53

62

140

 

12.9

140

140

140

123

107

90

74

131

 

14.1

131

131

131

114

98

81

65

 

 

 

 

57

141

 

13.0

141

141

141

124

107

91

74

134

 

14.3

134

134

134

117

100

84

67

 

72

168

 

13.3

140

121

102

84

65

47

28

157

 

14.5

138

119

100

82

63

44

26

6250

67

154

 

13.1

154

150

131

113

94

75

57

145

 

14.3

145

145

127

108

90

71

53

62

143

 

12.9

143

143

143

124

106

87

68

133

 

14.2

133

133

133

115

96

77

59

 

 

 

 

57

143

 

13.0

143

143

143

124

106

87

68

136

 

14.3

136

136

136

117

99

80

61

 

 

 

 

Temperature

of

Air on

Condenser Coil 125°F

 

 

 

 

 

 

 

 

 

 

 

 

72

137

 

15.6

94

83

73

62

51

41

30

1 These capacities are gross ratings. For net

 

3750

67

127

 

15.5

112

102

91

80

70

59

48

 

 

 

 

capacity, deduct air blower motor, MBh = 3.415

 

62

116

 

15.3

116

113

102

91

81

70

59

 

 

 

 

 

 

 

 

 

57

121

 

15.5

121

116

105

95

84

73

63

 

 

x kW. Refer to the appropriate Blower Perfor-

 

 

72

139

 

15.7

105

92

79

67

54

41

29

 

 

mance Table for the kW of the supply air

 

 

4375

67

129

 

15.5

125

112

99

87

74

61

49

 

 

blower motor.

 

 

 

 

 

 

 

62

118

 

15.3

118

116

111

99

86

73

61

2

 

These ratings include condenser fan motors

 

 

57

123

 

15.5

123

120

115

102

90

77

64

 

 

(total 1 kW) and the compressor motors but

 

 

72

141

 

15.7

115

100

86

71

57

42

28

 

 

 

 

 

 

 

not the supply air blower motor.

 

 

 

5000

67

131

 

15.5

131

122

108

93

78

64

49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

62

120

 

15.3

120

120

120

106

91

77

62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

125

 

15.6

125

125

125

110

95

81

66

 

 

 

 

 

 

 

 

 

 

 

72

144

 

15.7

125

109

92

75

59

42

26

 

 

 

 

 

 

 

 

 

 

5625

67

133

 

15.5

133

131

115

99

82

65

49

 

 

 

 

 

 

 

 

 

 

62

122

 

15.4

122

122

122

106

89

72

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

127

 

15.6

127

127

127

110

94

77

60

 

 

 

 

 

 

 

 

 

 

 

72

146

 

15.7

135

117

98

80

61

42

24

 

 

 

 

 

 

 

 

 

 

6250

67

136

 

15.6

136

136

123

104

86

67

48

 

 

 

 

 

 

 

 

 

 

62

124

 

15.4

124

124

124

105

87

68

49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

129

 

15.6

129

129

129

110

92

73

54

 

 

 

 

 

 

 

 

 

 

Johnson Controls Unitary Products

11

Page 11
Image 11
York manual DJ 150 12 1/2 TON Cooling Capacity, Mbh

DJ 150 specifications

The York DJ 150 is an impressive addition to the world of DJ equipment, designed to cater to both amateur and professional DJs. It elegantly combines a range of features that enhance the performance of any DJ while ensuring ease of use and portability. This versatile piece of equipment stands out for its rich sound quality, intuitive controls, and robust build.

One of the primary features of the York DJ 150 is its powerful 150-watt output, which guarantees clear and vibrant sound, even in larger venues. DJs can expect exceptional audio fidelity, allowing them to experiment with a range of genres without losing the clarity and punch of their tracks. The built-in equalizer provides users with the ability to tailor the audio output to suit various environments, whether it’s a small gathering or a large party.

The DJ 150 boasts a range of connectivity options, making it easy to integrate with other devices. With USB, RCA, and AUX inputs, DJs can connect a variety of sources, such as laptops, smartphones, and mixers, ensuring maximum versatility. Additionally, it supports Bluetooth connectivity, allowing for wireless streaming from compatible devices, which adds to the convenience of the DJ setup.

In terms of technology, the York DJ 150 incorporates innovative features such as a built-in sampler and effects system. This allows DJs to layer sounds, add effects in real-time, and create unique mixes that stand out. The simple interface and well-placed controls make it easy to navigate through various settings and effects, ideal for those who may be new to DJing.

Portability is another key characteristic of the York DJ 150. Its lightweight design and durable carrying case make it easy to transport, ensuring that DJs can set up and break down their equipment quickly, no matter the location. This aspect is particularly beneficial for mobile DJs who frequently travel for gigs.

Overall, the York DJ 150 is an exceptional choice for anyone looking to elevate their DJ experience. With its powerful sound, versatile connectivity, innovative technology, and portability, it caters to a wide range of users, making it a valuable asset in any DJ's arsenal. Whether for casual use or professional events, the DJ 150 promises the reliable performance and quality that modern DJs demand.