12.5 Ton Model Number Nomenclature

D J 150 N15 A 2 A AA 4 0 1 2 4 A

Product Category

D = A/C, Single Pkg., R-22

Product Identifier

J = 12.5 Ton 11.3 EER A/C

Nominal Cooling Capacity

150 = 12.5 Ton

Heat Type and Nominal Heat Capacity

C00 = Cooling Only. No heat installed

Gas Heat Options

N15 = 150 MBH Output Aluminized Steel

N20 = 200 MBH Output Aluminized Steel

S15 = 150 MBH Output Stainless Steel

S20 = 200 MBH Output Stainless Steel

Electric Heat Options

E18 = 18 KW

E24 = 24 KW

E36 = 36 KW

E54 = 54 KW

Airflow

A = Std. Motor

B = Std. Motor/Econo./Barometric Relief (Downflow

Only)

C = Std. Motor/Econo./Power Exhaust (Downflow Only)

D = Std. Motor/Motorized Damper (Downflow Only)

E = Std. Motor/Horizontal Economizer (No Baro.)

F = Std. Motor/Slab Econo./Power Exhaust

(Downflow Only)

G = Std. Motor/Slab Econo./Barometric Relief

(Downflow Only)

N = Hi Static Mtr.

P = Hi Static Mtr./Econo./Barometric Relief

(Downflow Only)

Q = Hi Static Mtr./Econo./Power Exhaust

(Downflow Only)

R = Hi Static Mtr./Motorized Damper (Downflow Only)

S = Hi Static Mtr./Horizontal Economizer (No Baro.)

T = Hi Static Mtr./Slab Econo./Power Exhaust

(Downflow Only)

U = Hi Static Mtr./Slab Econo./Barometric Relief

(Downflow only)

Voltage

2 = 208/230-3-60

4 = 460-3-60

5 = 575-3-60

Product Style

A = Style A

B = Style B

C = Style C

Configuration Options (not required for all units)

These four digits will not be assigned until a quote is requested, or an order placed.

SS Drain Pan

CPC Controller, DFS, APS

Johnson Controller UNT 1126 (N2 protocol), DFS, APS

Honeywell Controller, DFS, APS

Novar Controller, DFS, APS

Simplicity IntelliComfort Controller

Simplicity IntelliComfort Controller w/ModLinc

York Commercial Comfort System (YCCS) Rtu Controller

2" Pleated filters

BAS Ready Unit with Belimo Economizer

Shipping Bag

Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned

Product Generation

4 = Fourth Generation

Additional Options

AA = None

RC = Coil Guard, Shipping Bag & American Flag

AB = Phase Monitor

TA = Technicoat Condenser Coil

AC = Coil Guard

TJ = Technicoat Evaporator Coil

AD = Dirty Filter Switch

TS = Technicoat Evaporator & Condenser Coils

AE = Phase Monitor & Coil Guard

 

AF = Phase Monitor & Dirty Filter Switch

 

AG = Coil Guard & Dirty Filter Switch

 

AH = Phase Monitor, Coil Guard & Dirty Filter Switch

 

 

 

ZZ= If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18.

Installation Options

A = No Options Installed

B = Option 1

C = Option 2

D = Options 1 & 2

E = Option 3

F = Option 4

G = Options 1 & 3

H = Options 1 & 4

J = Options 1, 2 & 3

K = Options 1, 2, & 4

L = Options 1,3 & 4

M = Options 1, 2, 3, & 4

N = Options 2 & 3

P = Options 2 & 4

Q = Options 2, 3, & 4

R = Options 3 & 4

S = Option 5

T = Options 1 & 5

U = Options 1, 3, & 5

V = Options 1, 4, & 5

W = Options 1, 3, 4, & 5

X = Options 3 & 5

Y = Options 4 & 5

Z = Options 3, 4 & 5

Options

1 = Disconnect

2 = Non-Pwr'd Conv. Outlet

3 = Smoke Detector S.A.

4 = Smoke Detector R.A.

5 = Pwr'd Conv. Outlet