295421-YTG-B-0707

ELECTRICAL DATA - 1- 208/230 - 1-60

 

Heater1

 

MAX. STATIC

 

Total Heat2

 

 

 

KW Staging3

 

 

Models

 

& MIN. CFM

 

 

 

 

 

 

 

 

 

 

 

KW

MBH

W1 Only

W2 Only

W1 + W2

Model

 

 

 

Static

Tap

208V

240V

208V

240V

208V

240V

208V

240V

208V

240V

 

 

 

 

2HK*6500506B

 

 

Low

3.8

5.0

13.0

17.1

3.8

5.0

3.8

5.0

3.8

5.0

F4FP024H06T2*

2HK*6500806B

 

0.5

Low

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

 

2HK*6501006B

 

 

Low

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

 

2HK*6500506B

 

 

Low

3.8

5.0

13.0

17.1

3.8

5.0

3.8

5.0

3.8

5.0

F4FP030H06T2*

2HK*6500806B

 

0.5

Low

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

2HK*6501006B

 

Low

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

 

 

 

 

2HK16501506B

 

 

High

11.3

15.0

38.6

51.2

3.8

5.0

7.5

10.0

11.3

15.0

 

2HK*6500506B

 

 

Low

3.8

5.0

13.0

17.1

3.8

5.0

3.8

5.0

3.8

5.0

 

2HK*6500806B

 

 

Low

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

F4FP036H06T2*

2HK*6501006B

0.5

Low

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

 

2HK16501506B

 

 

Med

11.3

15.0

38.6

51.2

3.8

5.0

7.5

10.0

11.3

15.0

 

2HK16501906B4

 

 

High

13.2

17.6

45.1

60.1

2.8

3.8

10.4

13.8

13.2

17.6

 

2HK*6500506B

 

 

Low

3.8

5.0

13.0

17.1

3.8

5.0

3.8

5.0

3.8

5.0

F4FP040H06T2*

2HK*6500806B

 

0.5

Low

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

2HK*6501006B

 

Low

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

 

 

 

 

2HK16501506B

 

 

High

11.3

15.0

38.6

51.2

3.8

5.0

7.5

10.0

11.3

15.0

 

2HK*6500506B

 

 

Low

3.8

5.0

13.0

17.1

3.8

5.0

3.8

5.0

3.8

5.0

F4FP042H06T2*

2HK*6500806B

 

0.5

Low

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

2HK*6501006B

 

Low

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

 

 

 

 

2HK16501506B

 

 

Low

11.3

15.0

38.6

51.2

3.8

5.0

7.5

10.0

11.3

15.0

 

2HK*6500506B

 

 

Low

3.8

5.0

13.0

17.1

3.8

5.0

3.8

5.0

3.8

5.0

F4FP045H06T2*

2HK*6500806B

 

0.5

Low

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

2HK*6501006B

 

Med

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

 

 

 

 

2HK16501506B

 

 

High

11.3

15.0

38.6

51.2

3.8

5.0

7.5

10.0

11.3

15.0

 

2HK16500506B

 

 

Med-Low

3.8

5.0

13.0

17.1

3.8

5.0

3.8

5.0

3.8

5.0

 

2HK16500806B

 

 

Med-Low

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

F5FP048H06T2*

2HK*6501006B

 

0.5

Med-Low

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

2HK16501506B

 

Med-Low

11.3

15.0

38.6

51.2

3.8

5.0

7.5

10.0

11.3

15.0

 

 

 

 

2HK16502006B

 

 

Med-Low

15.0

20.0

51.2

68.3

3.8

5.0

11.3

10.0

15.0

20.0

 

2HK16502506B

 

 

Med-Low

18.8

25.0

64.2

85.3

3.8

5.0

11.3

15.0

18.8

25.0

 

2HK*6501006B

 

 

Med

3.8

5.0

13.0

17.1

3.8

5.0

3.8

5.0

3.8

5.0

 

2HK16500806B

 

 

Med

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

F5FP060H06T2*

2HK16501006B

 

0.5

Med

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

2HK16501506B

 

Med

11.3

15.0

38.6

51.2

3.8

5.0

7.5

10.0

11.3

15.0

 

 

 

 

2HK16502006B

 

 

Med

15.0

20.0

51.2

68.3

3.8

5.0

7.5

10.0

15.0

20.0

 

2HK16502506B

 

 

Med

18.8

25.0

64.2

85.3

3.8

5.0

11.3

15.0

18.8

25.0

 

2HK*6500806B

 

 

1335

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

 

2HK*6501006B

 

 

1335

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

F4FV060H06T2*

 

 

0.5

 

 

 

 

 

 

 

 

 

 

 

2HK16501506B

 

1335

11.3

15.0

38.6

51.2

3.8

5.0

7.5

10.0

11.3

15.0

 

2HK16502006B

 

 

1335

15.0

20.0

51.2

68.3

3.8

5.0

7.5

10.0

15.0

20.0

 

2HK16502506B

 

 

1335

18.8

25.0

64.2

85.3

3.8

5.0

11.3

15.0

18.8

25.0

NOTE: All models available with factory installed horizontal drain pan.

1.0 or as follows: 0 = No Breaker, 1 = Breaker.

2.See Conversion Table below:

3.If first stage heat or 66 is connected to W1, otherwise refer to this table.

4.2HK16501906B only applies to F4FP036 Model.

KW & MBH CONVERSIONS - FOR TOTAL POWER INPUT REQUIREMENT

FOR 230V

OPERATION MULTIPLY

240V

TABULATED KW & MBH BY

.918

8

Unitary Products Group

Page 8
Image 8
York F*FP, F*FV specifications KW & MBH Conversions for Total Power Input Requirement, Total Heat2, W1 Only W2 Only W1 + W2

F*FV, F*FP specifications

York F*FV and F*FP are two advanced HVAC systems designed for commercial and industrial applications, delivering optimized performance and energy efficiency. These models are part of York's commitment to innovative climate control solutions that meet the diverse needs of modern buildings.

The F*FV series is known for its flexible configurations, catering to various indoor environments. This series is engineered with powerful variable-speed fans that adjust airflow according to real-time demand, ensuring not only comfort but also significant energy savings. The integration of advanced inverter technology allows for precise control of compressor speed, which results in lower energy consumption while maintaining stable temperature conditions.

On the other hand, the F*FP series is distinguished by its high cooling and heating capacities, making it suitable for larger facilities such as manufacturing plants and data centers. These systems utilize scroll compressors, which are recognized for their reliability and quiet operation. The F*FP's design prioritizes easy maintenance, with service access points strategically placed to minimize downtime.

Both series utilize advanced refrigerants that comply with environmental regulations, ensuring that users can expect eco-friendly operation. The systems are equipped with intelligent control features, including Wi-Fi connectivity and remote monitoring capabilities. This allows facility managers to oversee operations and make adjustments in real time, leading to enhanced energy management and operational efficiency.

York has equipped both F*FV and F*FP systems with comprehensive diagnostic tools. These features aid technicians in troubleshooting and maintaining the systems, thereby extending their lifespan and ensuring optimal performance. The user-friendly interfaces make it simple for operators to navigate system settings, monitor performance metrics, and receive alerts for maintenance needs.

Notably, both series are designed with robust construction to withstand harsh operating conditions while providing low noise levels, an essential characteristic for environments where minimal disturbance is critical. The systems are also versatile, supporting various installation types, including rooftop, split, and packaged configurations.

In summary, York’s F*FV and F*FP series stand out in the HVAC market, offering a combination of energy efficiency, cutting-edge technology, and ease of use. These systems provide reliable climate control to meet the evolving needs of commercial and industrial spaces, ensuring comfort while promoting sustainability. Whether it’s the versatility of the F*FV or the high capacity of the F*FP, York delivers solutions that enhance productivity and operational effectiveness.