OPERATION

B-4

RECOMMENDED PROCESSES

GMAW (CV, Synergic CV, Pulse, STT™, Power, Pulse on Pulse™, Push-Pull)

FCAW

SMAW

GTAW (Lift Start only)

Solid wires .025" to 1/16"

Cored wires .035" to 5/64"

Cored wires .035" to 3/32" when configured for "extra torque"

EQUIPMENT LIMITATIONS

Works only on ArcLink® or LincNet™ Power Wave® power sources.

When operating on LincNet™ power sources, not all features are available.

Maximum gun length is 25ft.(7.6m) for push-only sys- tems.

Maximum gun length is 50ft.(15.2m) for push-pull systems.

Spool guns do not work with the POWER FEED® 25M.

A remote control/foot amptrol and a push-pull gun may not be connected to the POWER FEED® 25M simultaneously.

Maximum spool size is 12 in. (305 mm) diameter

Maximum spool weight is 44 lb (20 kg).

Maximum control cable length is 200 ft (61 m).

Other gun bushings are required for welding guns that do not have a Magnum® (Tweco #2-#4 compati- ble) back end.

No more than 2 wire feeders may be connected to one ArcLink® power source at a time.

RECOMMENDED POWER SOURCES

Power Wave® 355M

Power Wave® 455M

Power Wave® 455M/STT

Power Wave® 655/R

POWER FEED® 25M