B-34OPERATION

EXAMPLE 1 - 2 STEP TRIGGER: Simple operation The simplest trigger operation occurs with a 2 Step trigger and the Start, Crater and Burnback functions all set to OFF. (See Figure B.19)

For this sequence,

PREFLOW:

Shielding gas begins to flow immediately when the gun trigger is pulled.

STRIKE:

After preflow time expires, the power source regulates to the welding output and wire is advanced towards the work piece at the strike Run-In WFS. If an arc is not established within 1.5 seconds, the wire feed speed will jump to the welding wire feed speed.

WELD:

The power source output and the wire feed speed con- tinue at the weld settings for as long as the trigger is pulled.

POSTFLOW: As soon as the trigger is released, the power source output and the wire feed speed are turned OFF. Shielding gas continues until the post flow timer expires.

B-34

to Section TOC

to Master TOC

Idle

Shielding On

Trigger Pulled

Arc Established

Preflow

Strike

FIGURE B.19

2 Step Trigger

Start = OFF

Crater = OFF

Burnback = OFF

Weld

Trigger Released

Pos tflow

Idle

Return

Return

Gas

Off

Power

Weld

1.5 sec max.

Source

Output

Off

 

Return to Section TOC

Return to Master TOC

WFS

Weld

Run-in

Off

POWER FEED® 25M