ACCESSORIES

C-6

INSTALLATION OF THE

K590-6 WATER

4. Use a 5/16" nut driver to remove the screws holding

 

 

the water cooling cover on the case front of the inner

COOLING KIT

module and on the rear of the case.

 

Return to Section

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master

Return to Master TOC

Return to Master TOC

Return to Master TOC

WARNING

ELECTRIC SHOCK can kill.

• Turn the input power OFF at the dis- connect switch before working on this equipment.

Do not touch electrically hot parts.

Only qualified personnel should install, use or service this equipment.

------------------------------------------------------------------------

The K590-6 components are rated up to 70 psi (5 bar) and 158°F (70°C). Use a coolant fluid that is compati- ble with the water cooler and the gun.

Tools required:

3/8" wrench

5/16" nut driver

medium flat bladed screw driver

cutting tool

1.Turn power off at the welding power source.

2.Remove the screws securing the case to the inner module using a 3/8" wrench.

3.Remove the module from the case by lifting the front of the module approximately .25" (6 mm) and then sliding forward.

5.Install the fitting and hose assembly to the case front. Route the hoses along the bottom of the inner module and out through the cutout of the cover. Slide the module back into the case.

6.Secure the module to the case with the screws. (Shown in Step 2)

7.Install the fitting assembly to the rear of the case

8.Slide the hose clamps on to the hoses. Trim the hoses to length so that they lay flat on the case bot- tom. Slide the hoses on to the fittings on the case rear and secure with the hose clamps.

POWER FEED® 25M