Section TOC
Master TOC
TROUBLESHOOTING AND REPAIR |
VOLTAGE SENSE PC BOARD TEST (continued)
FIGURE F.1 – PLUG J1 AND J2 LOCATIONS
Return to
Return to Section TOC
Return to
Return to Master TOC
2 3 J2
J1
4 5
2 | NOTE: Inspect the molex plug con- | |
nector pins on the Voltage Sense | ||
| ||
| Board. If any of them are gold plat- | |
| ed the P.C. board should be | |
| replaced. | |
|
|
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
PROCEDURE
1.Remove input power from the wire feed unit.
2.Using the 3/8 in. nut driver, remove the cover from behind the wire reel.
3.Locate the voltage sense PC board and plugs J1 and J2. Do not remove the plugs from the voltage sense pc board. Refer to Figure F.1.
4.Apply the correct input power (from the POWER FEED® 25M control cable) to the wire feeder. With the gun trigger activated, check for approximately 12 VDC at plug J1 pin 1 (+) to pin 4
5.With the gun trigger activated and arc voltage present at the conductor block, check for arc voltage from plug J1 pin 3 (lead 67) to the workpiece. If actual arc voltage is NOT pre- sent, check the continuity of lead 67 from the conductor block to plug J1 pin 3 on the voltage sense PC board.
6.If the actual arc voltage IS present at plug J1 pin 3 (lead 67), then check for arc voltage from plug J2 pin 2 (lead 67B) to the workpiece. See wiring diagram.
7.If the 12 VDC IS present in step #4 and the arc voltage IS present in step #5 but the arc volt- age is NOT present in step #6 (lead 67A), the voltage sense PC board may be faulty.
8.Remove all input power from the wire feeder unit.
9.Install the wire feeder cover with the 3/8 in. nut driver.