OPERATION | ||
| 11. |
|
The
WARNING
ELECTRIC SHOCK can kill.
• Turn the input power OFF at the welding power source before installation or changing drive rolls and/or guides.
• Do not touch electrically live parts.
• When inching with the gun trigger, electrode and drive mechanism are "hot" to work and ground and could remain energized several seconds after the gun trigger is released.
• Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.
• Only qualified personnel should perform mainte- nance work.
STATUS LED |
|
|
|
|
|
| STAT US |
| |
(See Table B.1) |
|
|
| |
|
|
| ||
|
|
|
| |
|
|
|
|
|
The status LED indicates system status. Normal oper- | ||||
ation is a steady green light. |
|
|
|
|
Note: During normal | ||||
and/or green as the equipment performs self tests. |
| TABLE B.1 |
|
|
LED condition | Definition |
Steady green | System okay. The power source and wire feeder are communicating normally. |
Blinking green. | Occurs during a reset and indicates the power source is identifying each component in the system. This is |
| normal for up to 15 seconds after |
Blinking green, fast | Indicates that one or more pieces of ArcLink equipment are not mapping properly. Check the DIP switch set- |
| ting on the wire feeders. |
Blinking green fol- | |
lowed by blinking | red and green, errors are present in the system. Count the error code before the machine is turned |
red. | below. |
| Error codes are detailed in the Troubleshooting Section E. Individual code digits are flashed in red with a long |
| pause between digits. After each error code the LED will flash green and codes will repeat. There may be more |
| than one error code indicated. Record the red flash count (error code) for reference before turning unit off. |
| To clear the error, turn the power source OFF, and then back ON to reset. See Troubleshooting Section E. |
|
|