B-6

OPERATION

B-6

 

11. ON-OFF SWITCH

 

The On-Off Switch turns the wire feeder power on and off. It does not control the power to the welding power source.

WARNING

ELECTRIC SHOCK can kill.

• Turn the input power OFF at the welding power source before installation or changing drive rolls and/or guides.

• Do not touch electrically live parts.

• When inching with the gun trigger, electrode and drive mechanism are "hot" to work and ground and could remain energized several seconds after the gun trigger is released.

• Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

• Only qualified personnel should perform mainte- nance work.

------------------------------------------------------------------------

STATUS LED

 

 

 

 

 

 

STAT US

 

(See Table B.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The status LED indicates system status. Normal oper-

ation is a steady green light.

 

 

 

 

Note: During normal power-up, the LED may flash red

and/or green as the equipment performs self tests.

 

TABLE B.1

 

 

LED condition

Definition

Steady green

System okay. The power source and wire feeder are communicating normally.

Blinking green.

Occurs during a reset and indicates the power source is identifying each component in the system. This is

 

normal for up to 15 seconds after power-up, or if the system configuration is changed during operation.

Blinking green, fast

Indicates that one or more pieces of ArcLink equipment are not mapping properly. Check the DIP switch set-

 

ting on the wire feeders.

Blinking green fol-

Non-recoverable system fault. If the power source or wire feeder status LED is flashing any combination of

lowed by blinking

red and green, errors are present in the system. Count the error code before the machine is turned off-see

red.

below.

 

Error codes are detailed in the Troubleshooting Section E. Individual code digits are flashed in red with a long

 

pause between digits. After each error code the LED will flash green and codes will repeat. There may be more

 

than one error code indicated. Record the red flash count (error code) for reference before turning unit off.

 

To clear the error, turn the power source OFF, and then back ON to reset. See Troubleshooting Section E.

 

 

POWER FEED® 25M

Page 24
Image 24