B-25

OPERATION

B-25

Return to Section TOC

Section TOC

SET-UP FEATURES MENU

The Setup Menu gives access to the set-up configura- tion. Stored in the set-up configuration are user para- meters that generally need to be set only at installation. The parameters are grouped as follows:

P.1 through P.99 Unsecured Parameters (always adjustable)

P.101 through P.199 Diagnostic Parameters (always read only)

P.501 through P.599 Secured Parameters (accessi- ble only though a p.c. or palm application.)

To access the set-up menu, press the right and left but- tons of the MSP4 panel simultaneously. Note that the set-up menu cannot be accessed if the system is weld- ing, or if there is a fault (The status LED is not solid green).

Change the value of the blinking parameter by rotating the SET knob.

After changing a parameter it is necessary to press the right hand button to save the new setting. Pressing the left button will cancel the change.

To exit the set-up menu at any time, press the right and left buttons of the MSP4 panel simultaneously. Alternately, 1 minute of inactivity will also exit the set- up menu.

The following list includes all possible parameters in ArcLink® equipment. Not all of the parameters listed may appear for your system. Refer to Table B.1 for active parameters.

Return to

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

 

 

TABLE B.1

 

 

 

 

 

 

 

 

 

Unsecured Parameters

 

POWER FEED®

POWER

POWER

 

 

 

10M (All Models)

FEED® 25M

FEED® 10A

PARAMETER

DESCRIPTION

 

P.0

Exit set-up menu

 

￿

￿

￿

 

￿

￿

￿

P.1

WFS Units

 

 

 

 

 

 

P.2

Arc Display Mode

 

￿

￿

￿

P.4

Trigger Memory Recall

 

￿

￿

 

 

P.5

Trigger Procedure Change

 

￿

￿

 

 

P.6

Stall Factor Adjustment

 

￿

￿

 

 

P.7

Gun Offset Adjustment

 

￿

￿

 

 

P.8

TIG Gas Control

 

￿

￿

￿

 

P.11

Set Timers

 

 

 

 

 

 

 

 

 

P.12

Travel Options

 

 

 

￿

P.13

Adjust Arc Force

 

 

 

￿

 

 

 

 

 

 

P.80

Sense From Studs

 

￿

￿

 

 

P.99

Show Test Modes

 

￿

￿

￿

 

 

 

 

 

 

 

Diagnostic

Parameters

 

 

 

 

 

 

 

 

 

 

￿

 

 

 

 

 

P.100

View Diagnostics

 

￿

￿

 

P.101

View Event Logs

 

￿

￿

￿

P.102

View Fatal Logs

 

￿

￿

￿

P.103

View Software Version

 

￿

￿

￿

P.104

View Hardware Version

 

￿

￿

￿

P.105

View Welding Software

 

￿

￿

￿

P.106

View Ethernet IP Address

 

￿

￿

￿

P.107

View Power Source Type

 

￿

￿

￿

 

 

 

 

 

 

 

POWER FEED® 25M

Page 43
Image 43
Lincoln Electric SVM185-A service manual SET-UP Features Menu, Power Feed, 10M All Models, Feed 10A, Parameter Description