F-8

TROUBLESHOOTING AND REPAIR

F-8

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

Major physical or electrical damage

1. Contact your local authorized

1. Contact the Lincoln Electric

is evident when the sheet metal

Lincoln Electric Field Service

Service Department, 1-888-

cover(s) are removed.

 

Facility for assistance.

935-3877.

 

 

 

 

No wire feed, solenoid or arc volt-

1. The gun trigger may be faulty.

1. Check the continuity of leads

age. The STATUS LED’s are

Check or replace.

from the gun trigger receptacle

steady green.

 

 

to plug J85.

See wire drive

 

 

2. Check panel connections and

wiring diagram.

 

 

switch(s) for proper operation.

 

 

 

 

 

2. The wire drive feedhead board

 

 

 

may be faulty.

 

 

 

 

No control of wire feed speed. All

1. Check P9 plug and set at feed-

1. Perform the Tach Feedback

Test.

 

STATUS LEDs are steady green.

head control.

 

 

 

The preset wire feed speed is

 

2. The wire drive feedhead board

adjustable on the front panel.

 

 

may be faulty.

 

 

 

No welding arc voltage when the

1. The Power source may unable to

1. Make certain the Power Wave

gun trigger is activated. The wire

produce welding output due to a

power source is functioning

feeds normally and the gas sole-

thermal fault or other malfunction.

correctly. (Green Status LED)

noid functions properly. The STA-

Check STATUS LED on Power

2. Check weld + work cable rout-

TUS LEDs are steady green on the

Source. See PowerWave®

wire drive unit.

 

Troubleshooting.

ing.

 

 

 

 

The wire feed speed does not

1. The run in and weld wire feed

1. Perform the Current Transducer

change when welding current is

speeds may be set to the same

Test in POWERWAVE® service

established. The WFS stays at

value. Set run in speed to a

manual.

 

the run-in speed. The STATUS

value that gives best starting

 

 

LEDs are steady green.

 

results.

2. If the run in wire feed speed can-

 

 

 

not be adjusted, perform the

 

 

 

Tach Feedback Test and also

 

 

 

the Drive Motor Test.

 

 

 

3. The wire drive feedhead board

 

 

 

may be faulty.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.