REMOTE SENSE LEAD SPECIFICATIONS

Welding with Multiple Arcs: ( See Figure A.7)

Special care must be taken when more than one arc is welding simultaneously on a single part. Arc blow and arc interference may occur or be magnified. Each power source requires a work lead from the work stud to the welding fixture. Do not combine all of the work leads into one lead. Performing welding in the direction away from the work leads. Connect all of the work sense leads from each power source to the work piece at the end of the weld, such that they are out of the path of the weld current. See Figure A.7

For the best results when pulse welding, set the wire size and wire feed speed the same for all the arcs. When these parameters are identical, the pulsing fre- quency will be the same, helping to stabilize the arcs.

LOADING SPOOLS OF WIRE

WARNING

Keep hands, hair, clothing and tools away from rotating equipment.

Do not wear gloves when threading wire or changing wire spool.

Only qualified personnel should install, use or service this equipment.

------------------------------------------------------------------------

Loading 10 to 15 lb. (4.5 – 6.8kg) Spools.

A K468 spindle adapter is required for loading 2" (51mm) wide spools on 2" (51mm) spindles. Use a K468 spindle adapter for loading 2-1/2" (64mm) wide spools.

1.Squeeze the release bar on the retaining collar and remove it from the spindle.

2.Place the spindle adapter on the spindle, aligning the spindle brake pin with the hole in the adapter.

3.Place the spool on the spindle and align the adapter brake tab with one of the holes in the back side of the spool. An indicator mark on the end of the spin- dle shows the orientation of the brake tab. Be cer- tain the wire feeds off of the spool in the proper direction.

4.Re-install the retaining collar. Make sure that the release bar snaps out and that the retaining collar fully engages the groove on the spindle.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

FIGURE A.7

CONNECLEADS ATTHALLESENSEEND

DIRECTION OF THE WELD

OF TRAVEL

CONNECT ALL

WORK LEADS AT

THE BEGINNING

OF THE WELD

POWER FEED® 25M

Page 17
Image 17
Lincoln Electric SVM185-A service manual Remote Sense Lead Specifications, Loading Spools of Wire