TROUBLESHOOTING AND REPAIR

F-4

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

The ammeter on the POWER

1. Make sure the DIP switches are

1. Perform the Current Transducer

FEED® 25M does not function

configured correctly for the weld-

Test in the Power Source

 

properly even though the STATUS

ing process and polarity used.

Service Manual.

 

LEDs are steady green.

 

See Setting DIP Switches in

 

 

 

 

the Wire Drive in the

2. The control board, located in the

 

 

Installation section of this manu-

power source, may be faulty.

 

 

 

al.

 

 

 

 

2. Check the following connections

 

 

 

 

on the POWER WAVE®

 

 

 

 

machine. Check for loose or

 

 

 

 

faulty connections between plug

 

 

 

 

J90 at the current transducer and

 

 

 

 

plug J21 on the Power Source

 

 

 

 

control board.

 

 

 

 

 

The display and/or indicator LEDs

1. Check for loose or faulty connec-

1. Check suspected potentiometer

do not change when their corre-

tions between the encoder panel

and/or switches for correct resis-

sponding switches and or knobs

and the Control Box control

tances and operation.

 

are activated or turned.

 

board.

2. Refer to machine schematics for

 

 

 

 

 

2. Check for loose or faulty connec-

lead numbers and voltages.

 

 

 

tions between the appropriate

 

 

 

 

switches and the Control Box

3. The Control Box control board

 

 

 

control board.

may be faulty.

 

 

 

 

 

The mode and/or settings change

1. Contact “powerwave software.com”

 

 

while welding under normal condi-

for the latest updated software.

 

 

tions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 