B-31

OPERATION

B-31

Return to Section TOC

Return to Section TOC

Four items show on the MSP4 panel.

Memory Value

High Limit

Low Limit

Parameter Name

One of these items will flash to indicate which item will change when the MSP4 encoder is rotated. Press the right button on the MSP4 panel to select the item to change.

Memory Value

 

High Limit

 

Low Limit

 

 

 

WAVEFORM CONTROL TECHNOLOGY

IR PORT

200Lo ==

180200

 

Hi

 

 

 

SETUP

 

Weld WFS

WELD MODE

 

START OPTIONS

ARC CONTROL

 

END OPTIONS

SET

Parameter Name

The memory value must always be less than or equal to the high limit, and greater than or equal to the low limit.

After setting limits, press the memory button with the flashing LED. The MSP4 will ask to save or discard the limit changes just made. Press the left MSP4 for but- ton (YES) to save and enable the limits and exit. Press the right MSP4 button (NO) to exit and leave limits unchanged.

Enabling/Disabling Limits

Enable/Disable

Limits: Press

10 seconds

MMEMORYM

PROCEDURE

A GUN B

1 2 3

HOLD 2 SECONDS TO SAVE

4 5 6

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

The Limits Setup menu shows a list of all parameters available for the weld mode stored in the memory cho- sen. For example, if limits are being set for a stick (SMAW) mode, parameters such as Run-in WFS and Postflow will not appear.

To lock a parameter to a specific value that cannot be changed, set the high and low limits to the same value.

 

WAVEFORM CONTROL TECHNOLOGY

IR PORT

200Lo ==

180200

 

Hi

 

 

 

SETUP

 

Weld WFS

WELD MODE

 

START OPTIONS

ARC CONTROL

 

END OPTIONS

 

SET

 

 

Rotate to

Press to

 

Change

select item

 

Value.

to change.

Limits for each memory may be enabled or disabled by pressing and hold the appropriate memory button for 10 seconds. Release the memory button when the MSP4 display shows the following:

 

WAVEFORM CONTROL TECHNOLOGY

 

Memory 1

IR PORT

Limits

 

SETUP

 

Enable/Disable

WELD MODE

START OPTIONS

ARC CONTROL

END OPTIONS

 

SET

Press the left MSP4 button (YES) to enable limits or the right MSP4 button (NO) to disable limits. Disabling limits does not change any limits values that may have been previously set.

WAVEFORM CONTROL TECHNOLOGY

 

Enable

IR PORT

Limits?

 

SETUP

Yes

No

WELD MODE

START OPTIONS

ARC CONTROL

END OPTIONS

 

SET

POWER FEED® 25M

Page 49
Image 49
Lincoln Electric SVM185-A service manual High Limit, Low Limit, Parameter Name