ELECTRICAL DATA - 1 Ø
|
| Min. Circuit Ampacity | Max. O.C.P.1 Amps/Type | 75°C Wire Size - AWG | |||||||
Models | Heater Model |
| Circuit |
|
| Circuit |
|
| Circuit |
| |
1st | 2nd | 3rd | 1st | 2nd | 3rd | 1st | 2nd | 3rd | |||
|
| ||||||||||
|
| 208/240V | 208/240V | 208/240V | 208/240V | 208/240V | 208/240V | 208/240V | 208/240V | 208/240V | |
F4FP030H06T2* | 2HK16501506B | 25.8/28.7 | 45.1/52.1 | — | 30/30 | 50/60 | — | 10/10 | 8/6 | — | |
F4FP036H06T2* | 2HK16501506B | 26.8/29.5 | 45.1/52.1 | — | 30/30 | 50/60 | — | 10/10 | 8/6 | — | |
2HK16501906B2 | 38.3/42.6 | 45.7/52.6 | — | 40/45 | 50/60 | — | 8/8 | 8/6 | — | ||
| |||||||||||
F4FP040H06T2* | 2HK16501506B | 25.8/28.7 | 45.1/52.1 | — | 30/30 | 50/60 | — | 10/10 | 8/6 | — | |
F4FP042H06T2* | 2HK16501506B | 28.1/30.5 | 45.1/52.1 | — | 30/35 | 50/60 | — | 10/8 | 8/6 | — | |
F4FP045H06T2* | 2HK16501506B | 26.6/29.3 | 45.1/52.1 | — | 30/30 | 50/60 | — | 10/10 | 8/6 | — | |
| 2HK16501506B | 32.8/35.6 | 45.1/52.1 | — | 35/40 | 50/60 | — | 8/8 | 8/6 | — | |
F5FP048H06T2* |
|
|
|
|
|
|
|
|
|
| |
2HK16502006B | 55.3/61.6 | 45.1/52.1 | — | 60/70 | 50/60 | — | 6/4 | 8/6 | — | ||
| 2HK16502506B | 32.8/35.6 | 45.1/52.1 | 45.1/52.1 | 35/40 | 50/60 | 50/60 | 8/8 | 8/6 | 8/6 | |
| 2HK16501506B | 32.8/35.6 | 45.1/52.1 | — | 35/40 | 50/60 | — | 8/8 | 8/6 | — | |
F5FP060H06T2* |
|
|
|
|
|
|
|
|
|
| |
2HK16502006B | 55.3/61.6 | 45.1/52.1 | — | 60/70 | 50/60 | — | 6/4 | 8/6 | — | ||
| 2HK16502506B | 33.8/35.6 | 45.1/52.1 | 45.1/52.1 | 35/40 | 50/60 | 50/60 | 8/8 | 8/6 | 8/6 | |
| 2HK16501506B | 33.0/34.8 | 45.1/52.1 | — | 35/35 | 50/60 | — | 8/8 | 8/6 | — | |
F4FV060H06T2* |
|
|
|
|
|
|
|
|
|
| |
2HK16502006B | 55.2/60.8 | 45.1/52.1 | — | 60/70 | 50/60 | — | 6/4 | 8/6 | — | ||
| 2HK16502506B | 33.0/34.8 | 45.1/52.1 | 45.1/52.1 | 35/35 | 50/60 | 50/60 | 8/8 | 8/6 | 8/6 |
1.OCP = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse.
2.2HK16501906B only applies to F4FP036 Model.
ELECTRICAL DATA - 3∅ - 208/230-3-60
|
| MAX. STATIC |
| Total Heat1 |
|
|
| KW Staging2 |
|
| ||||
Models | Heater Model | & MIN. CFM |
|
|
|
|
| |||||||
KW | MBH | W1 Only | W2 Only | W1 + W2 | ||||||||||
|
| Static | Tap | 208V | 240V | 208V | 240V | 208V | 240V | 208V | 240V | 208V | 240V | |
F4FP024H06T2* | 2HK06501025B | 0.5 | Low | 7.5 | 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 | |
F4FP030H06T2* | 2HK06501025B | 0.5 | Low | 7.5 | 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 | |
2HK06501525B | 0.5 | High | 11.3 | 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | ||
| ||||||||||||||
F4FP036H06T2* | 2HK06501025B | 0.5 | Low | 7.5 | 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 | |
2HK06501525B | 0.5 | High | 11.3 | 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | ||
| ||||||||||||||
F4FP040H06T2* | 2HK06501025B | 0.5 | Low | 7.5 | 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 | |
2HK06501525B | 0.5 | High | 11.3 | 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | ||
| ||||||||||||||
F4FP042H06T2* | 2HK06501025B | 0.5 | Low | 7.5 | 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 | |
2HK06501525B | 0.5 | Low | 11.3 | 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | ||
| ||||||||||||||
F4FP045H06T2* | 2HK06501025B | 0.5 | Med | 7.5 | 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 | |
2HK06501525B | 0.5 | High | 11.3 | 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | ||
| ||||||||||||||
F5FP048H06T2* | 2HK06501025B | 0.5 | Med Low | 7.5 | 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
2HK06501525B | 0.5 | Med Low | 11.3 | 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | ||
| ||||||||||||||
F5FP060H06T2* | 2HK06501025B | 0.5 | Med | 7.5 | 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 5.0 | 7.5 | 10.0 | |
2HK06501525B | 0.5 | Med | 11.3 | 15.0 | 38.6 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | ||
| ||||||||||||||
F4FV060H06T2* | 2HK06501025B | 0.5 | 1335 | 7.5 | 10.0 | 25.6 | 34.1 | 3.8 | 5.0 | 7.5 | 10.0 | 7.5 | 10.0 | |
2HK06501525B | 0.5 | 1335 | 11.3 | 15.0 | 38.8 | 51.2 | 3.8 | 5.0 | 7.5 | 10.0 | 11.3 | 15.0 | ||
|
1.See Conversion Table below.
2.If first stage heat is connected to W1/66, otherwise refer to Table below.
KW & MBH CONVERSIONS - FOR TOTAL POWER INPUT REQUIREMENT
FOR 230V
OPERATION MULTIPLY
240V
TABULATED KW & MBH BY
.918