331471-YTG-A-0507

DIMENSIONS

3/8” 20(Opening)

3/4” Flange

A

C

B

22”

20 1/4” D

BOTTOM

OPENING

DIMENSIONS

COIL - MC

DIMENSIONS - MC COILS

 

 

 

 

 

Refrigerant

Factory

 

 

 

 

 

Line Size*

Model

A

B

C

D

Installed

 

 

 

 

 

 

 

TXV (R22)

 

 

 

 

 

Liquid

Vapor

 

 

 

 

 

 

 

 

MC18A2AH1

14.5

22

13 3/8

13.5

3/8

3/4

A

 

 

 

 

 

 

 

 

MC18A3XH1

14.5

22

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

MC18B2AH1

14.5

22

13 3/8

13.5

3/8

3/4

A

 

 

 

 

 

 

 

 

MC18B3XH1

14.5

22

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

MC24A2AH1

14.5

26.5

13 3/8

13.5

3/8

3/4

A

 

 

 

 

 

 

 

 

MC24A3XH1

14.5

26.5

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

MC24B2AH1

17.5

26.5

16 3/8

16.5

3/8

3/4

A

 

 

 

 

 

 

 

 

MC24B3XH1

17.5

26.5

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

MC30A2AH1

14.5

26.5

13 3/8

13.5

3/8

3/4

A

 

 

 

 

 

 

 

 

MC30A3XH1

14.5

26.5

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

MC30B2AH1

17.5

26.5

16 3/8

16.5

3/8

3/4

A

 

 

 

 

 

 

 

 

MC30B3XH1

17.5

26.5

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

MC35B2AH1

17.5

22

16 3/8

16.5

3/8

3/4

A

 

 

 

 

 

 

 

 

MC35C2AH1

21

22

19 7/8

20

3/8

3/4

A

 

 

 

 

 

 

 

 

MC35B3XH1

17.5

22

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

MC35C3XH(1,2)

21

26.5/22

19 7/8

20

3/8

3/4

None

 

 

 

 

 

 

 

 

MC36A2AH1

14.5

26.5

13 3/8

13.5

3/8

7/8

A

 

 

 

 

 

 

 

 

MC36A3XH1

14.5

26.5

13 3/8

13.5

3/8

7/8

None

 

 

 

 

 

 

 

 

MC36B2AH1

17.5

26.5

16 3/8

16.5

3/8

7/8

A

 

 

 

 

 

 

 

 

MC36B3XH1

17.5

26.5

16 3/8

16.5

3/8

7/8

None

 

 

 

 

 

 

 

 

All MC coils include a factory installed horizontal drain pan. (3X) = Models require field installed TXV.

 

 

 

 

 

Refrigerant

Factory

 

 

 

 

 

Line Size

Model

A

B

C

D

Installed

 

 

 

 

 

 

 

TXV (R22)

 

 

 

 

 

Liquid

Vapor

 

 

 

 

 

 

 

 

MC36C2AH1

21

26.5

19 7/8

20

3/8

7/8

A

 

 

 

 

 

 

 

 

MC36C3XH1

21

26.5

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

MC42B2CH1

17.5

32

16 3/8

16.5

3/8

7/8

C

 

 

 

 

 

 

 

 

MC42B3XH1

17.5

32

16 3/8

16.5

3/8

7/8

None

 

 

 

 

 

 

 

 

MC42C2CH1

21

32

19 7/8

20

3/8

7/8

C

 

 

 

 

 

 

 

 

MC42C3XH1

21

32

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

MC43C2CH1

21

26.5

19 7/8

20

3/8

7/8

C

 

 

 

 

 

 

 

 

MC43C3XH1

21

26.5

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

MC48C2CH1

21

32

19 7/8

20

3/8

7/8

C

 

 

 

 

 

 

 

 

MC48C3XH1

21

32

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

MC48D2CH1

24.5

32

23 3/8

23.5

3/8

7/8

C

 

 

 

 

 

 

 

 

MC48D3XH1

24.5

32

23 3/8

23.5

3/8

7/8

None

 

 

 

 

 

 

 

 

MC60D2CH1

24.5

32

23 3/8

23.5

3/8

7/8

C

 

 

 

 

 

 

 

 

MC60D3XH1

24.5

32

23 3/8

23.5

3/8

7/8

None

 

 

 

 

 

 

 

 

MC61D2CH1

24.5

36

23 3/8

23.5

3/8

7/8

C

 

 

 

 

 

 

 

 

MC61D3XH1

24.5

36

23 3/8

23.5

3/8

7/8

None

 

 

 

 

 

 

 

 

MC62C2CH1

21.0

36

19 7/8

20

3/8

7/8

C

 

 

 

 

 

 

 

 

MC62C3XH1

21.0

36

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

MC62D2CH1

24.5

36

23 3/8

23.5

3/8

7/8

C

 

 

 

 

 

 

 

 

MC62D3XH1

24.5

36

23 3/8

23.5

3/8

7/8

None

 

 

 

 

 

 

 

 

All MC coils include a factory installed horizontal drain pan. (3X) = Models require field installed TXV.

*Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.

† Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.

Unitary Products Group

11

Page 11
Image 11
York MH specifications Coil MC Dimensions MC Coils