331471-YTG-A-0507

B

3/8” 20(Opening) C

(Opening)

12”

A22”

D

20 1/4”

BOTTOM

OPENING

DIMENSIONS

COIL - PC

DIMENSIONS - PC COILS

 

 

 

 

 

Refrigerant

Factory

Model

A

B

C

D

Line Size*

Installed

 

 

TXV

 

 

 

 

 

Liquid

Vapor

 

 

 

 

 

(R22)

 

 

 

 

 

 

 

 

PC18A2AN1

14.5

17 3/4

13 3/8

13.5

3/8

3/4

A

 

 

 

 

 

 

 

 

PC18A3XN1

14.5

17 3/4

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC18B2AN1

14.5

17

13 3/8

13.5

3/8

3/4

A

 

 

 

 

 

 

 

 

PC18B3XN1

14.5

17

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC24A2AN1

14.5

21 7/8

13 3/8

13.5

3/8

3/4

A

 

 

 

 

 

 

 

 

PC24A3XN1

14.5

21 7/8

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC24B2AN1

17.5

21 3/8

16 3/8

16.5

3/8

3/4

A

 

 

 

 

 

 

 

 

PC24B3XN1

17.5

21 3/8

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC30A2AN1

14.5

21 7/8

13 3/8

13.5

3/8

3/4

A

 

 

 

 

 

 

 

 

PC30A3XN1

14.5

21 7/8

13 3/8

13.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC30B2AN1

17.5

21 3/8

16 3/8

16.5

3/8

3/4

A

 

 

 

 

 

 

 

 

PC30B3XN1

17.5

21 3/8

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC35B2AN1

17.5

18 7/8

16 3/8

16.5

3/8

3/4

A

 

 

 

 

 

 

 

 

PC35C2AN1

21

18 3/4

19 7/8

20

3/8

3/4

A

 

 

 

 

 

 

 

 

PC35B3XN1

17.5

18 7/8

16 3/8

16.5

3/8

3/4

None

 

 

 

 

 

 

 

 

PC35C3XN1

21

18 3/4

19 7/8

20

3/8

3/4

None

 

 

 

 

 

 

 

 

PC36A2AN1

14.5

23 7/8

13 3/8

13.5

3/8

7/8

A

 

 

 

 

 

 

 

 

PC36A3XN1

14.5

23 7/8

13 3/8

13.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC coils are not available with a factory installed horizontal drain pan. (3X) = Models require field installed TXV.

 

 

 

 

 

Refrigerant

Factory

Model

A

B

C

D

Line Size

Installed

 

 

TXV

 

 

 

 

 

Liquid

Vapor

 

 

 

 

 

(R22)

 

 

 

 

 

 

 

 

PC36B2AN1

17.5

23 1/8

16 3/8

16.5

3/8

7/8

A

 

 

 

 

 

 

 

 

PC36B3XN1

17.5

23 1/8

16 3/8

16.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC36C2AN1

21

22 7/8

19 7/8

20

3/8

7/8

A

 

 

 

 

 

 

 

 

PC36C3XN1

21

22 7/8

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

PC42B2CN1

17.5

27 5/8

16 3/8

16.5

3/8

7/8

C

 

 

 

 

 

 

 

 

PC42B3XN1

17.5

27 5/8

16 3/8

16.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC42C2CN1

21

27 1/8

19 7/8

20

3/8

7/8

C

 

 

 

 

 

 

 

 

PC42C3XN1

21

27 1/8

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

PC43C2CN1

21

22 5/8

19 7/8

20

3/8

7/8

C

 

 

 

 

 

 

 

 

PC43C3XN1

21

22 5/8

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

PC48C2CN1

21

25 3/8

19 7/8

20

3/8

7/8

C

 

 

 

 

 

 

 

 

PC48C3XN1

21

25 3/8

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

PC48D2CN1

24.5

24 5/8

23 3/8

23.5

3/8

7/8

C

 

 

 

 

 

 

 

 

PC48D3XN1

24.5

24 5/8

23 3/8

23.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC60C2CN1

21

27 1/2

19 7/8

20

3/8

7/8

C

 

 

 

 

 

 

 

 

PC60C3XN1

21

27 1/2

19 7/8

20

3/8

7/8

None

 

 

 

 

 

 

 

 

PC60D2CN1

24.5

26 7/8

23 3/8

23.5

3/8

7/8

C

 

 

 

 

 

 

 

 

PC60D3XN1

24.5

26 7/8

23 3/8

23.5

3/8

7/8

None

 

 

 

 

 

 

 

 

PC coils are not available with a factory installed horizontal drain pan. (3X) = Models require field installed TXV.

*Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.

† Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.

Unitary Products Group

13

Page 13
Image 13
York MH specifications Coil PC Dimensions PC Coils