20 | 3/8” |
|
|
| C |
| |
(Opening) |
| ||
|
| ||
| 3/4” Flange |
|
|
|
| B |
|
| A | 22” |
|
|
| 20 1/4” | D |
|
|
| BOTTOM |
|
|
| OPENING |
|
|
| DIMENSIONS |
COIL - FC
DIMENSIONS - FC COILS
|
|
|
|
| Refrigerant | Factory | |
|
|
|
|
| Line Size* | ||
Model | A | B | C | D | Installed | ||
|
|
|
|
|
| TXV (R22) | |
|
|
|
|
| Liquid Vapor | ||
|
|
|
|
|
|
|
|
FC18A2AN1 | 14.5 | 18 | 13 3/8 | 13.5 | 3/8 | 3/4 | A |
FC18A3XN1 | 14.5 | 18 | 13 3/8 | 13.5 | 3/8 | 3/4 | None |
FC18B2AN1 | 14.5 | 18 | 13 3/8 | 13.5 | 3/8 | 3/4 | A |
FC18B3XN1 | 14.5 | 18 | 13 3/8 | 13.5 | 3/8 | 3/4 | None |
FC24A2AN1 | 14.5 | 22 | 13 3/8 | 13.5 | 3/8 | 3/4 | A |
FC24A3XN1 | 14.5 | 22 | 13 3/8 | 13.5 | 3/8 | 3/4 | None |
FC24B2AN1 | 17.5 | 22 | 16 3/8 | 16.5 | 3/8 | 3/4 | A |
FC24B3XN1 | 17.5 | 22 | 16 3/8 | 16.5 | 3/8 | 3/4 | None |
FC30A2AN1 | 14.5 | 22 | 13 3/8 | 13.5 | 3/8 | 3/4 | A |
FC30A3XN1 | 14.5 | 22 | 13 3/8 | 13.5 | 3/8 | 3/4 | None |
FC30B2AN1 | 17.5 | 22 | 16 3/8 | 16.5 | 3/8 | 3/4 | A |
FC30B3XN1 | 17.5 | 22 | 16 3/8 | 16.5 | 3/8 | 3/4 | None |
FC35B2AN1 | 17.5 | 20 | 16 3/8 | 16.5 | 3/8 | 3/4 | A |
FC35C2AN1 | 21 | 20 | 19 7/8 | 20 | 3/8 | 3/4 | A |
FC35B3XN2 | 17.5 | 20 | 16 3/8 | 16.5 | 3/8 | 3/4 | None |
FC35C3XN(1,2) | 21 | 24.5/20 | 19 7/8 | 20 | 3/8 | 3/4 | None |
FC36A2AN1 | 14.5 | 24.5 | 13 3/8 | 13.5 | 3/8 | 7/8 | A |
FC36A3XN1 | 14.5 | 24.5 | 13 3/8 | 13.5 | 3/8 | 7/8 | None |
FC36B2AN1 | 17.5 | 24.5 | 16 3/8 | 16.5 | 3/8 | 7/8 | A |
FC36B3XN1 | 17.5 | 24.5 | 16 3/8 | 16.5 | 3/8 | 7/8 | None |
FC coils are not available with a factory installed horizontal drain pan. (3X) = Models require field installed TXV.
|
|
|
|
| Refrigerant | Factory | |
|
|
|
|
| Line Size† | ||
Model | A | B | C | D | Installed | ||
|
|
|
|
|
| TXV (R22) | |
|
|
|
|
| Liquid Vapor | ||
|
|
|
|
|
|
|
|
FC36C2AN1 | 21 | 24.5 | 19 7/8 | 20 | 3/8 | 7/8 | A |
FC36C3XN1 | 21 | 24.5 | 19 7/8 | 20 | 3/8 | 7/8 | None |
FC42B2CN1 | 17.5 | 28 | 16 3/8 | 16.5 | 3/8 | 7/8 | C |
FC42B3XN1 | 17.5 | 28 | 16 3/8 | 16.5 | 3/8 | 7/8 | None |
FC42C2CN1 | 21 | 28 | 19 7/8 | 20 | 3/8 | 7/8 | C |
FC42C3XN1 | 21 | 28 | 19 7/8 | 20 | 3/8 | 7/8 | None |
FC43C2CN1 | 21 | 24.5 | 19 7/8 | 20 | 3/8 | 7/8 | C |
FC43C3XN1 | 21 | 24.5 | 19 7/8 | 20 | 3/8 | 7/8 | None |
FC48C2CN1 | 21 | 28 | 19 7/8 | 20 | 3/8 | 7/8 | C |
FC48C3XN1 | 21 | 28 | 19 7/8 | 20 | 3/8 | 7/8 | None |
FC48D2CN1 | 24.5 | 28 | 23 3/8 | 23.5 | 3/8 | 7/8 | C |
FC48D3XN1 | 24.5 | 28 | 23 3/8 | 23.5 | 3/8 | 7/8 | None |
FC60C2CN1 | 21 | 28 | 19 7/8 | 20 | 3/8 | 7/8 | C |
FC60C3XN1 | 21 | 28 | 19 7/8 | 20 | 3/8 | 7/8 | None |
FC60D2CN1 | 24.5 | 28 | 23 3/8 | 23.5 | 3/8 | 7/8 | C |
FC60D3XN1 | 24.5 | 28 | 23 3/8 | 23.5 | 3/8 | 7/8 | None |
FC62C2CN1 | 21 | 32 | 19 7/8 | 20 | 3/8 | 7/8 | C |
FC62C3XN1 | 21 | 32 | 19 7/8 | 20 | 3/8 | 7/8 | None |
FC62D2CN1 | 24.5 | 32 | 23 3/8 | 23.5 | 3/8 | 7/8 | C |
FC62D3XN1 | 24.5 | 32 | 23 3/8 | 23.5 | 3/8 | 7/8 | None |
FC coils are not available with a factory installed horizontal drain pan. (3X) = Models require field installed TXV.
*Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin
† Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin
12 | Unitary Products Group |