York TCHD18 THRU 60 Unit, Air Handler, Coil, Cooling, Model, MODEL1, Rated, Net Mbh, Seer, Sens

Models: TCHD18 THRU 60

1 28
Download 28 pages 42.2 Kb
Page 6
Image 6
UNIT

556454-YTG-A-0210

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

AIR HANDLER

COIL

 

 

 

COOLING

 

 

MODEL

MODEL

W

MODEL1

RATED

 

NET MBH

SEER

EER

CFM

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

13 SEER AC WITH AHP / SHP / AHX / F*FP

 

 

 

 

 

AHX18

17

630

 

18.2

13.1

14.25

11.75

 

AHX24

17

590

 

18.3

13.0

14.25

11.75

TCHD18S41S3

AHX30

17

610

 

18.6

13.3

14.50

12.00

F6FP018

17

600

 

17.9

12.6

13.50

11.25

 

 

 

F6FP024

17

600

 

18.5

13.1

14.00

11.50

 

F6FP030

17

620

 

18.5

13.2

14.00

11.50

 

AHP24

17

850

 

23.0

16.8

13.15

11.05

 

AHX18

17

835

 

23.2

17.2

14.00

11.50

 

AHX24

17

800

 

23.6

17.3

14.00

12.75

 

AHX30

17

820

 

23.8

17.8

14.50

12.75

TCHD24S41S3

AHX36

21

815

 

24.2

18.1

15.00

12.25

 

F*FP030

17

800

 

23.0

16.7

13.10

11.00

 

F6FP024

17

840

 

23.4

17.4

14.00

11.50

 

F6FP030

17

850

 

23.4

17.4

13.75

11.25

 

F6FP036

21

855

 

23.8

17.9

14.25

11.75

 

AHP36

21

1000

 

28.4

21.2

13.75

12.20

 

AHX30

17

1025

 

28.4

21.3

14.50

12.50

 

AHX36

21

1005

 

29.0

21.7

15.25

13.25

 

AHX42

21

990

 

29.4

22.1

15.50

13.75

 

AHX48

24

1090

 

29.8

23.0

15.50

13.75

TCHD30S41S3

F*FP030

17

1000

 

27.6

20.0

13.20

11.85

F*FP036

21

1000

 

27.8

20.6

13.40

12.00

 

 

 

F*FP040

21

1000

 

27.8

20.4

13.40

12.00

 

F6FP030

17

1035

 

28.2

20.9

13.75

12.00

 

F6FP036

21

980

 

28.2

20.7

14.50

12.75

 

F6FP042

21

1065

 

29.6

22.4

15.25

13.50

 

F6FP048

24

1055

 

28.0

21.0

14.50

12.50

 

AHP36

21

1200

 

34.2

25.0

14.00

12.15

 

AHX36

21

1225

 

34.4

25.7

14.75

12.50

 

AHX42

21

1190

 

35.0

25.9

15.25

12.75

 

AHX48

24

1255

 

35.2

26.3

15.25

12.75

 

AHX60

24

1300

 

35.6

26.8

15.00

12.75

 

F*FP036

21

1200

 

33.0

23.8

13.00

11.35

TCHD36S41S3

F*FP040

21

1200

 

33.0

24.0

13.00

11.40

 

F*FP042

21

1200

 

33.0

24.0

13.00

11.40

 

F5FP048

24

1250

 

35.0

25.8

15.20

13.00

 

F6FP036

21

1210

 

33.4

24.3

13.75

11.75

 

F6FP042

21

1290

 

35.2

26.4

14.75

12.50

 

F6FP048

24

1125

 

32.2

23.3

14.00

11.75

 

F6FP060

24

1240

 

35.2

26.3

15.00

12.75

 

AHP/SHP60

24

1600

 

45.5

33.2

13.40

11.50

 

AHX48

24

1660

 

47.0

34.6

13.75

11.75

 

AHX60

24

1680

 

47.5

34.8

13.50

11.75

TCHD48S41S3

F5FP048

24

1700

 

47.5

35.0

13.75

12.00

 

F5FP060

24

1700

 

46.0

33.4

13.35

11.55

 

F6FP048

24

1625

 

45.0

33.2

13.00

11.00

 

F6FP060

24

1710

 

48.0

35.0

13.50

11.50

TCHD60S41S3

AHX60

24

1905

 

57.5

40.2

13.00

11.00

F6FP060

24

1710

 

56.5

38.7

13.00

11.00

 

 

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

— = Not applicable.

6

Johnson Controls Unitary Products

Page 6
Image 6
York TCHD18 THRU 60 warranty Unit, Air Handler, Coil, Cooling, Model, MODEL1, Rated, Net Mbh, Seer, Sens