COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)

UNIT

MODEL

FURNACE

MODEL

COIL

MODEL1

W

COOLING

RATEDNet MBHSEER EER

CFM TOTAL SENS.

 

 

13 SEER AC WITH VARIABLE SPEED FURNACES2

 

 

 

 

Y*9C*B12

HD36

17

635

18.5

12.9

14.75

12.35

 

Y*9C*C16

HD36

21

595

18.6

12.9

15.00

12.50

 

Y*(8,L)C*A12

UC18A

14

620

18.2

13.1

14.55

12.10

 

Y*(8,L)C*B12

UC18B

17

580

18.0

12.7

14.50

12.15

 

Y*9C*B12

UC18B

17

610

18.2

13.1

14.70

12.25

 

Y*(8,L)C*A12

UC24A

14

640

18.6

13.4

14.75

12.30

 

Y*(8,L)C*B12

UC24B

17

575

18.4

13.1

15.00

12.45

TCHD18S41S3

Y*9C*B12

UC24B

17

610

18.7

13.4

14.85

12.40

Y*(8,L)C*A12

UC30A

14

640

18.6

13.4

14.75

12.30

 

 

Y*(8,L)C*B12

UC30B

17

575

18.4

13.1

15.00

12.45

 

Y*9C*B12

UC30B

17

610

18.7

13.4

14.85

12.40

 

Y*(8,L)C*A12

UC36A

14

645

18.1

13.3

14.60

12.15

 

Y*(8,L)C*B12

UC36B

17

650

18.1

13.3

14.70

12.20

 

Y*9C*B12

UC36B

17

635

18.1

13.4

14.75

12.25

 

Y*(8,L)C*C16

UC36C

21

595

17.9

12.8

14.60

12.25

 

Y*9C*C16

UC36C

21

595

17.9

12.8

14.75

12.30

 

T*(8,L)X*A12

FC/MC/PC24A

14

775

23.4

17.3

14.50

11.75

 

T*(8,L)X*B12

FC/MC/PC24B

17

835

23.6

17.7

14.50

12.00

 

T*9X*B12

FC/MC/PC24B

17

775

23.4

17.3

14.50

11.75

 

T*(8,L)X*A12

FC/MC/PC30A

14

775

23.4

17.2

14.25

11.75

 

T*(8,L)X*B12

FC/MC/PC30B

17

835

23.6

17.7

14.50

12.00

 

T*9X*B12

FC/MC/PC30B

17

775

23.4

17.2

14.25

12.00

 

T*(8,L)X*A12

FC/MC/PC32A

14

800

23.6

17.6

14.75

12.00

 

T*(8,L)X*B12

FC/MC/PC35B

17

850

23.6

17.8

14.75

12.00

 

T*(8,L)X*C16

FC/MC/PC35C

21

625

22.8

15.9

14.25

11.75

 

T*(8,L)X*C20

FC/MC/PC35C

21

885

23.6

18.1

14.75

12.00

 

T*9X*B12

FC/MC/PC35B

17

785

23.8

17.7

14.75

12.00

 

T*9X*C16

FC/MC/PC35C

21

715

23.4

16.9

14.50

12.00

 

T*9X*C20

FC/MC/PC35C

21

825

23.6

17.6

14.50

12.00

 

T*(8,L)X*A12

FC/MC/PC36A

14

815

23.6

17.7

14.50

12.00

 

T*(8,L)X*B12

FC/MC/PC36B

17

835

23.8

17.8

14.75

12.00

 

T*(8,L)X*C16

FC/MC/PC36C

21

675

23.2

16.4

14.50

11.75

 

T*9X*B12

FC/MC/PC36B

17

775

23.6

17.6

14.50

12.00

TCHD24S41S3

T*9X*C16

FC/MC/PC36C

21

770

23.8

17.4

14.75

12.25

T*9X*C20

FC/MC/PC36C

21

810

23.6

17.6

14.50

12.00

 

 

T*(8,L)X*A12

FC/MC/PC37A

14

840

24.0

18.2

14.40

12.00

 

T*(8,L)X*B12

FC/MC/PC42B

17

865

24.2

18.4

14.75

12.00

 

T*(8,L)X*C16

FC/MC/PC42C

21

725

23.6

17.0

14.50

12.00

 

T*9X*B12

FC/MC/PC42B

17

805

23.8

17.8

14.75

12.00

 

T*9X*C16

FC/MC/PC42C

21

805

23.8

17.9

15.00

12.25

 

T*9X*C20

FC/MC/PC42C

21

790

23.6

17.6

14.50

12.00

 

T*(8,L)X*B12

FC/MC/PC43B

17

865

24.0

18.5

14.70

12.25

 

T*(8,L)X*C16

FC/MC/PC43C

21

655

23.0

16.2

14.25

11.75

 

T*9X*B12

FC/MC/PC43B

17

800

24.0

18.0

14.75

12.00

 

T*9X*C16

FC/MC/PC43C

21

735

23.6

17.2

14.75

12.00

 

T*9X*C20

FC/MC/PC43C

21

790

24.0

17.8

14.50

12.00

 

T*(8,L)X*C16

FC/MC/PC48C

21

685

23.6

16.8

14.50

12.00

 

T*9X*C16

FC/MC/PC48C

21

770

24.2

17.9

15.00

12.25

 

T*9X*C20

FC/MC/PC48C

21

815

24.2

18.2

14.75

12.00

 

T*(8,L)X*A12

HD36

14

815

23.0

17.0

14.25

11.75

 

T*(8,L)X*B12

HD36

17

855

23.0

17.0

14.25

11.75

 

T*(8,L)X*C16

HD36

21

855

23.0

17.0

14.25

11.75

For notes see Page 16.

Johnson Controls Unitary Products

9

Page 9
Image 9