28
P
A1: | PLACA MÃE DE CONTROLO |
A2: | PLACA MÃE DE EXPANSÃO |
| PARA CONTROLO |
A3: | PROTECTOR TÉRMICO DO |
| COMPRESSOR 1 |
A4: | PROTECTOR TÉRMICO DO |
| COMPRESSOR 2 |
B1: | ENTRADA DE ÁGUA |
| (SONDA NTC) |
B2: | SAÍDA DE ÁGUA DO CIRC. 1 |
| (SONDA NTC) |
B3: | TEMP. DE REFRIG. DO CONTROLO |
| DA VELOC. DO VENTILADOR |
| (BATERIA 1) (SONDA NTC) |
B5: | TEMP. DE REFRIG. DO CONTROLO |
| DA VELOC. DO VENTILADOR |
| (BATERIA 2) (SONDA NTC) |
C1, C2: | CONDENSADORES |
| DOS |
F1, F2: | FUSÍVEIS |
F2: | FUSÍVEL DO VARIADOR DE |
| VELOCIDADE |
FS: | CONTROLO DE CAUDAL |
FSC: | CONTROLO DA VELOCIDADE |
| DO VENTILADOR |
HP: | PRESSÓSTATO DE ALTA |
| (REARME AUTOMÁTICO) |
LP: | PRESSÓSTATO DE BAIXA |
| (REARME AUTOMÁTICO) |
K1: | DISPOSITIVO DE CONTACTO DO |
| COMPRESSOR 1 |
K2: | DISPOSITIVO DE CONTACTO |
| DO COMPRESSOR 2 |
K3: | DISPOSITIVO DE CONTACTO DA |
| BOMBA |
M1, M2: | COMPRESSORES 1 E 2 |
M3, M4: | VENTILADORES |
M5: | BOMBA |
PDW: | PRESSÓSTATO DIFERENCIAL DO |
| CIRCUITO DE ÁGUA |
Q:INTERRUPTORES AUTOMÁTICOS
RE: RESISTÊNCIA DO EVAPORADOR
RD: | RESISTÊNCIA DO DEPÓSITO |
R7: | RESISTÊNCIA DO CÁRTER DO COMPR.1 |
R8: | RESISTÊNCIA DO CÁRTER DO COMPR.2 |
RCH: | FRIO/CALOR REMOTO |
ROO: | ON/OFF REMOTO |
T1: | TRANSFORMADOR 230/24V |
01
(16)
1 3 5 13
Q3 2 4 6 14
1 3 5 13 K3
2 4 6 14
(16)
M5
02 | 03 | 04 | 05 |
| 6 |
| 7 |
400V,3 ~,50Hz,N, |
|
|
| Q5 | B |
| |
L1L2 L3 N |
|
| 63 | 3 x 25,16 ( ) 2,5(N) | |||
|
|
| 80 | ||||
|
|
|
|
| |||
Q4 |
|
|
|
|
|
|
|
30 m A | IO |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Q5 |
|
|
|
|
|
|
|
L1 L2 L3 N |
|
|
| T2 M1 |
| T2 M1 | |
|
|
| L | S1 | S1 | ||
"B" mm2 Cu |
|
| S2 | (13) | S2 | (26) | |
|
| A3 | A4 | ||||
L1 L2 L3 | N |
|
|
| T1 M2 |
| T1 M2 |
| Q6 |
|
|
|
| ||
Q7 |
|
|
|
|
|
| |
|
|
| N |
|
|
|
|
| 1 | 3 | 5 |
| 1 | 3 | 5 |
|
|
|
Q1 | 2 | 4 | 6 | Q2 | 2 | 4 | 6 | L | N Y | GND |
|
|
| ||||||||
|
|
|
|
|
|
|
| LOAD | F2 | |
|
|
|
|
|
|
|
|
| FSC | |
|
|
|
|
|
|
|
|
|
| |
K1 | 1 | 3 | 5 | K2 | 1 | 3 | 5 |
|
|
|
2 | 4 | 6 | 2 | 4 | 6 |
|
|
| ||
|
| F | S |
| ||||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| C1 | C2 |
|
| M1 |
|
|
|
|
|
| M3 | M4 |
|
|
|
|
| M2 |
|
|
| c | |
|
|
|
|
|
|
|
|
|
| d |
8 |
| 9 | |
|
| ||
|
| a | TP, |
21 | 21 |
| 400. |
22 | 22 | K2 | |
K1 |
|
| |
R7 | R8 |
| 3.50 |
|
|
b
Diagrama eléctrico
TK1, TK2: PROTECTORES TÉRMICOS DOS VENTILADORES M3 e M4
TL: | TERMINAL LOCAL DE CONTROLO |
V4V: | VÁLVULA DE QUATRO VIAS (APENAS NA |
|
OS COMPONENTES INCLUÍDOS NESTES QUADROS COM LINHAS NÃO SÃO FORNECIDOS PELO FABRICANTE
OS COMPONENTES INCLUÍDOS NESTES QUADROS COM LINHAS SÃO ACESSÓRIOS STANDARD
400.3.50