NORMAL FUNCTION OF THE AIR CONDITIONER

NORMAL FUNCTION OF THE AIR CONDITIONER

The following symptoms do not indicate air conditioner malfunction.

1. The system does not operate

• The system does not restart immediately after the ON/OFF button is pressed.

If the OPERATION lamp lights, the system is in normal condition.

The safety device operates to prevent overload of the system. After 3 minutes, the system will turn on again automatically.

The system does not restart immediately when TEMPERATURE SETTING changed.

If the OPERATION lamp lights, the system is in normal condition. If the timer light is flashing operation is being delayed by the safety device. It does not restart immediately because the compressor has been stopped and requested to start within the delay period. A safety device operates to prevent overload of the system.

After 3 minutes, the system will turn on again automatically.

The system does not start immediately after the power supply is turned on. Wait one minute until the microcomputer is prepared for operation.

1.1 White mist comes out of a unit

• When humidity is high during cooling operation. (In dusty locations or after construction work) If the inside of an indoor unit is contaminated, the temperature distribution inside a room may become uneven. It is necessary to clean the inside of the indoor unit. The unit should be cleaned by a qualified service person familiar with the unit.

• When the system is changed over to HEATING OPERATION or after DEFROST OPERATION. Moisture generated on the coil by the DEFROST becomes vapour and exists.

1.2Noise of air conditioners

A continuous flow “Shuh” sound is heard when the systems is in COOLING or DEFROST OPERATION. This is the sound of refrigerant

gas flowing through both indoor and outdoor units.

• A “Shuh” sound which is heard at the start or immediately after operation. It may also be heard

at the start or immediately after a DEFROST OPERATION.

This is the noise of refrigerant caused by the start and stop of the flow.

A “Pishi-pishi” squeaking sound is heard when the system is in operation or just after operation. Expansion and contraction of plastic parts caused by temperature change makes this noise.

1.3Dust from the units

Dust may blow out from the unit when starting after long off cycles.

Dust absorbed by the unit blows out.

The units give off odours. The unit absorbs the smell of rooms, furniture, cigarettes, etc., and then emits them.

PROTECTION FUNCTION

Auto Restart Function

The unit will automatically restart after loss of the electrical power supply. When power is restored; the unit operation will restart according to all parameters set before the loss of power.

ANTI-ICE and ANTI-OVERHEAT

This feature is used to prevent the indoor unit from freezing during cool or dry operation and overheating in heat mode. During execution of anti-ice operation and anti-overheating, the compressor will stop operating and the fan will continue to run until the coil temperature

reaches predetermined set points, at which time the unit will resume normal operation.

Low Voltage

The feature is used to protect against any damage to the unit caused by fluctuation of voltage. If voltage is lower than the lower limit for approximately 10 seconds or longer, compressor operation will be temporarily stopped. Normal operation will resume when the voltage returns above the set limit for a minimum of 10 seconds. If the time elapsed is less than 3 minutes

then the compressor start up will be delayed until 3 minutes has passed.

Filter Care and Filter Alarm

Replace Air Purifying filter if fitted.

The filters should be cleaned regularly, i.e, once a month, or more frequently depending on conditions. The control is equipped with a filter alarm; After a certain numbers of hours of operation, flashing lights will indicate that it is time to clean the filter. The alarm is reset by pressing the filter button or the transmitter.

MAINTENANCE

The units are designed to operate for long periods of time with a minimum of maintenance. However, the following operation must be performed regularly.

 

Maintenance Operations

Recommended Frequency

Air filter

Clean

Every month or more often if necessary

Unit casing

Clean

Every month or more often if necessary

Drain pan and evacuation piping

Clean and check for obstructions

Each season before start up*

Indoor/outdoor coils

Clean

Each season before start up*

Compressor

No need

 

* This operation must be carried out by qualified personnel only.

BEFORE MAINTENANCE

STurn off the main breaker or disconnect the main power supply.

Notes

• Don’t spill water : There is a danger of electric shock.

• Don’t used petrol, paint thinner, benzene or polishing agents : They may deform or scratch the unit.

CLEANING THE UNIT

Wipe the unit with a soft dry cloth only.

 

If the unit is very dirty, wipe it with a cloth soaked

Not more than

EMERGENCY OPERATION

Units are equipped with a switch to run emergency operation mode. Pushing the emergency switch turns the unit on;

pushing it again turns if off (toggle action). During emergency operation, the remote controller cannot be used and the power

LED light will flash at intervals, while the other LED lights will indicate the operation of the Diagnostic Codes.

In Emergency Operation and cooling units

the temperature will be set at 24°C and the fan on Auto. Heating units will switch to auto mode at a temperature set point of 24°C and the fan will run on auto mode.

After a power failure the unit restarts automatically in the same mode as before the failure, when power is resumed.

EMERGENCY OPERATION

in warm water (Not more than 40°C).

40°C

 

 

 

 

 

 

 

CLEANING THE AIR FILTER

1. Remove the air filter.

3. Drying

Open front grille

Drying the air filter by hair

and pull fillter

drying or direct sunlight.

outward front grille.

 

2. Cleaning

4. Reinstall the air filter.

If the fillter is very dirty,

 

clean it with water

Approx 30 °C

(approx 30°C).

 

TECHNICAL SPECIFICATION

Floor/Ceiling YOCC (YOEC-YODC) COOLING R-410A 50Hz Rev.291106

 

Set

 

YOCC12FSA(B)AAR

YOCC18FSA(B)AAR

YOCC24FSA(B)AAR

YOCC30FSA(B)ACR

YOCC30FSA(B)AAR

YOCC36FSA(B)AAR

YOCC36FSA(B)ACR

YOCC48FSA(B)ACR

YOCC60FSA(B)ACR

Model

Indoor unit

 

YOEC12FS-A(B)AR

YOEC18FS-A(B)AR

YOEC24FS-A(B)AR

YOEC30FS-A(B)CR

YOEC30FS-A(B)AR

YOEC36FS-A(B)AR

YOEC36FS-A(B)CR

YOEC48FS-A(B)CR

YOEC60FS-A(B)CR

Power supply

Outdoor Unit

Ph-V-Hz

YODC12FS-A(B)AR

YODC18FS-A(B)AR

YODC24FS-A(B)AR

YODC30FS-A(B)CR

YODC30FS-A(B)AR

YODC36FS-A(B)AR

YODC36FS-A(B)CR

YODC48FS-A(B)CR

YODC60FS-A(B)CR

 

1,220-240V,50Hz

1,220-240V,50Hz

1,220-240V,50Hz

3,380V,50Hz

1,220-240V,50Hz

1,220-240V,50Hz

3,380V,50Hz

3,380V,50Hz

3,380V,50Hz

 

 

Btu/h

12,000

18,000

24,000

30,000

30,000

36,000

36,000

48,000

60,000

 

Capacity

kW

3.5

5.4

7.1

9.2

9.2

10.5

10.5

14

17

Cooling

 

kcal/h

3,024

4,536

6,048

7,560

7,560

9,072

9,072

12,096

15,120

 

Input

W

1,200

1,900

2,600

3,450

3,450

3,800

3,800

4,900

5,800

 

Rated current

A

5.3

8.5

12.1

6.4

16.4

19.2

6.4

8.2

9.8

Moisture Removal

 

L/h

1.2

1.8

2.4

3

3

3.6

3.8

4.8

6

Max. input consumption

W

1,400

2,600

3,300

5,200

5,200

5,200

5,200

6,100

7,200

Max. current

 

A

7.2

13

16.5

8.8

25

26.3

8.8

10.3

12.2

Starting current

Type

A

26

36.8

61

97

97

97

61

66

67

 

 

ROTARY

ROTARY

ROTARY

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

SCROLL

 

Input

W

1,145

1,870

2,430

3,650

3,650

3,650

3,650

4,750

5,750

Compressor

Rated current (RLA)

A

5.3

8.75

11.4

6.58

17.65

17.65

6.58

8.22

9.77

Locked rotor Amp (LRA)

A

26

36.8

61

61

97

97

61

66

67

 

 

Thermal protector

 

Inner

Inner

Inner

Inner

Inner

Inner

Inner

Inner

Inner

 

Capacitor

μF

35/370μF/V

50/370μF/V

50/400μF/V

/

60μF/440V

60μF/440V

/

/

/

 

Input

W

104/98

110/104/98

110/104/98

142/134/132

142/134/132

142/134/132

142/134/132

118/108/101

118/108/101

Indoor fan motor

Capacitor

μF

1.5μF/450V

2.5μF/450V

2.5μF/450V

3.5μF/450V

3.5μF/450V

3.5μF/450V

3.5μF/450V

2.5μF/450V

2.5μF/450V

 

Speed (Hi/Mid/Low)

r/min

1,190/1,000/890

1,280/1,190/1,000

1,280/1,190/1,000

1,310/1,200/1,000

1,310/1,200/1,000

1,310/1,200/1,000

1,310/1,200/1,000

820/695/620

820/695/620

 

Number of rows

 

2

3

3

3

3

3

3

3

3

 

Fin spacing

mm

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

1.7

Indoor coil

Fin type

 

 

 

 

 

Hydrophilic aluminum

 

 

 

 

 

Tube outside dia.and type

mm

 

 

 

 

Ø9.53 innergroove tube

 

 

 

 

 

Coil length ￿ height ￿ width

mm

804￿254￿44

804￿254￿66

804￿254￿66

905￿203￿66

905￿203￿66

905￿203￿66

905￿203￿66

1,150￿254￿66

1,150￿254￿66

Indoor air flow (Hi/Mid/Low)

m3/h

600/480/400

800/600/500

1,000/900/700

1,200/1,000/800

1,400/1,200/1,000

1,400/1,200/1,000

1,400/1,200/1,000

2,000/1,800/1,600

2,000/1,800/1,600

Indoor noise level (Hi/Mid/Low)

dB(A)

43/41/38

43/41/38

45/43/40

45/43/40

45/43/40

45/43/40

45/43/40

47/45/42

47/45/42

 

Dimension (W*H*D)

mm

995￿660￿198

995￿660￿198

995￿660￿198

1,285￿660￿198

1,285￿660￿198

1,285￿660￿198

1,285￿660￿198

1,670￿680￿240

1,670￿680￿240

Indoor unit

Packing (W*H*D)

mm

1,075￿744￿278

1,075￿744￿278

1,075￿744￿278

1,365￿744￿278

1,365￿744￿278

1,365￿744￿278

1,365￿744￿278

1,764￿760￿329

1,764￿760￿329

 

Net/Gross weight

kg

30/37

30/37

30/37

34/42

34/42

34/42

34/42

52/62

52/62

Outdoor fan

Input

W

56

130

130

307

307

307

307

138+156

138+156

Capacitor

μF

2.5μF/450V

2.5μF/450V

3μF/450V

10μF/450V

10μF/450V

10μF/450V

10μF/450V

3.5￿2μF/450V

3.5￿2μF/450V

motor

Speed

r/min

800

750

800

740

740

740

740

800

800

 

Number of rows

 

2

2

2

2

2

2

2

2

2

 

Fin spacing

mm

1.4

1.7

1.5

1.7

1.7

1.7

1.7

1.8

1.8

Outdoor coil

Fin type

 

 

 

 

 

Unhydrophilic aluminum

 

 

 

 

 

Tube outside dia. and type

mm

 

 

 

 

Ø9.53, Innergroove tube

 

 

 

 

 

Coil length ￿ height ￿ width

mm

651￿559￿44

775￿660￿44

850￿810￿44

955￿915￿44

955￿915￿44

955￿915￿44

955￿915￿44

715￿1,220￿44

715￿1,220￿44

Outdoor air flow

 

m3/h

2,100

2,400

3,000

5,000

5,000

5,000

5,000

6,000

6,000

Outdoor noise level

 

dB(A)

43

48

55

57

57

57

57

58

58

 

Dimension (W*H*D)

mm

760￿590￿285

845￿695￿335

895￿860￿330

990￿960￿360

990￿960￿360

990￿960￿360

990￿960￿360

940￿1,245￿340

940￿1,245￿340

Outdoor unit

Packing (W*H*D)

mm

887￿655￿355

970￿770￿395

1,043￿915￿395

1,120￿1,090￿435

1,120￿1,090￿435

1,120￿1,090￿435

1,120￿1,090￿435

1,058￿1,380￿435

1,058￿1,380￿435

 

Net/Gross weight

kg

44/48

57/62

68/70

90/102

90/102

90/102

90/102

112/127

112/127

Refrigerant type/Quantity

g

R-410A/1,100

R-410A/2,000

R-410A/2,600

R-410A/3,000

R-410A/3,000

R-410A/3,000

R-410A/3,000

R-410A/3,700

R-410A/3,900

Design pressure (high side/low side)

MPa

4.2/2.5

4.2/2.5

4.2/2.5

4.2/2.5

4.2/2.5

4.2/2.5

4.2/2.5

4.2/2.5

4.2/2.5

Refrigerant

Liquid side

mm (inch)

6.35 (1/4)

6.35 (1/4)

9.53 (3/8)

12.7 (1/2)

12.7 (1/2)

12.7 (1/2)

12.7 (1/2)

12.7 (1/2)

12.7 (1/2)

Gas side

mm (inch)

12.7 (1/2)

12.7 (1/2)

16 (5/8)

19 (3/4)

19 (3/4)

19 (3/4)

19 (3/4)

19 (3/4)

19 (3/4)

piping

Max. pipe length

m

25

25

30

30

30

30

30

50

50

 

Max. difference in level

m

15

15

15

20

20

20

20

30

30

Operation temp

 

ºC

17~30

17~30

17~30

17~30

17~30

17~30

17~30

17~30

17~30

Ambient temp

 

ºC

18~45

18~45

18~45

18~45

18~45

18~45

18~45

18~45

18~45

Qty’per 20’& 40’Fcl

 

Pieces

63/138/155

49/104/126

44/94/101

27/55/62

27/55/62

27/55/62

27/55/62

25/50/54

25/50/54