NORMAL FUNCTION OF THE AIR CONDITIONER
The following symptoms do not indicate air conditioner malfunction.
1. The system does not operate
• The system does not restart immediately after the ON/OFF button is pressed.
If the OPERATION lamp lights, the system is in normal condition.
The safety device operates to prevent overload of the system. After 3 minutes, the system will turn on again automatically.
•The system does not restart immediately when TEMPERATURE SETTING changed.
If the OPERATION lamp lights, the system is in normal condition. If the timer light is flashing operation is being delayed by the safety device. It does not restart immediately because the compressor has been stopped and requested to start within the delay period. A safety device operates to prevent overload of the system.
After 3 minutes, the system will turn on again automatically.
•The system does not start immediately after the power supply is turned on. Wait one minute until the microcomputer is prepared for operation.
1.1 White mist comes out of a unit
• When humidity is high during cooling operation. (In dusty locations or after construction work) If the inside of an indoor unit is contaminated, the temperature distribution inside a room may become uneven. It is necessary to clean the inside of the indoor unit. The unit should be cleaned by a qualified service person familiar with the unit.
• When the system is changed over to HEATING OPERATION or after DEFROST OPERATION. Moisture generated on the coil by the DEFROST becomes vapour and exists.
1.2Noise of air conditioners
•A continuous flow “Shuh” sound is heard when the systems is in COOLING or DEFROST OPERATION. This is the sound of refrigerant
gas flowing through both indoor and outdoor units.
• A “Shuh” sound which is heard at the start or immediately after operation. It may also be heard
at the start or immediately after a DEFROST OPERATION.
This is the noise of refrigerant caused by the start and stop of the flow.
•A
1.3Dust from the units
•Dust may blow out from the unit when starting after long off cycles.
Dust absorbed by the unit blows out.
•The units give off odours. The unit absorbs the smell of rooms, furniture, cigarettes, etc., and then emits them.
PROTECTION FUNCTION
Auto Restart Function
•The unit will automatically restart after loss of the electrical power supply. When power is restored; the unit operation will restart according to all parameters set before the loss of power.
•This feature is used to prevent the indoor unit from freezing during cool or dry operation and overheating in heat mode. During execution of
reaches predetermined set points, at which time the unit will resume normal operation.
Low Voltage
•The feature is used to protect against any damage to the unit caused by fluctuation of voltage. If voltage is lower than the lower limit for approximately 10 seconds or longer, compressor operation will be temporarily stopped. Normal operation will resume when the voltage returns above the set limit for a minimum of 10 seconds. If the time elapsed is less than 3 minutes
then the compressor start up will be delayed until 3 minutes has passed.
Filter Care and Filter Alarm
•Replace Air Purifying filter if fitted.
•The filters should be cleaned regularly, i.e, once a month, or more frequently depending on conditions. The control is equipped with a filter alarm; After a certain numbers of hours of operation, flashing lights will indicate that it is time to clean the filter. The alarm is reset by pressing the filter button or the transmitter.
MAINTENANCE
The units are designed to operate for long periods of time with a minimum of maintenance. However, the following operation must be performed regularly.
| Maintenance Operations | Recommended Frequency |
Air filter | Clean | Every month or more often if necessary |
Unit casing | Clean | Every month or more often if necessary |
Drain pan and evacuation piping | Clean and check for obstructions | Each season before start up* |
Indoor/outdoor coils | Clean | Each season before start up* |
Compressor | No need |
|
* This operation must be carried out by qualified personnel only.
BEFORE MAINTENANCE
STurn off the main breaker or disconnect the main power supply.
Notes
• Don’t spill water : There is a danger of electric shock.
• Don’t used petrol, paint thinner, benzene or polishing agents : They may deform or scratch the unit.
CLEANING THE UNIT
Wipe the unit with a soft dry cloth only. |
|
If the unit is very dirty, wipe it with a cloth soaked | Not more than |
EMERGENCY OPERATION
•Units are equipped with a switch to run emergency operation mode. Pushing the emergency switch turns the unit on;
pushing it again turns if off (toggle action). During emergency operation, the remote controller cannot be used and the power
LED light will flash at intervals, while the other LED lights will indicate the operation of the Diagnostic Codes.
In Emergency Operation and cooling units
the temperature will be set at 24°C and the fan on Auto. Heating units will switch to auto mode at a temperature set point of 24°C and the fan will run on auto mode.
•After a power failure the unit restarts automatically in the same mode as before the failure, when power is resumed.
EMERGENCY OPERATION
in warm water (Not more than 40°C). | 40°C | |
|
|
|
|
|
|
| CLEANING THE AIR FILTER |
1. Remove the air filter. | 3. Drying |
Open front grille | Drying the air filter by hair |
and pull fillter | drying or direct sunlight. |
outward front grille. |
|
2. Cleaning | 4. Reinstall the air filter. |
If the fillter is very dirty, |
|
clean it with water | Approx 30 °C |
(approx 30°C). |
|
TECHNICAL SPECIFICATION
Floor/Ceiling YOCC
| Set |
| YOCC12FSA(B)AAR | YOCC18FSA(B)AAR | YOCC24FSA(B)AAR | YOCC30FSA(B)ACR | YOCC30FSA(B)AAR | YOCC36FSA(B)AAR | YOCC36FSA(B)ACR | YOCC48FSA(B)ACR | YOCC60FSA(B)ACR | |
Model | Indoor unit |
| ||||||||||
Power supply | Outdoor Unit | |||||||||||
| 3,380V,50Hz | 3,380V,50Hz | 3,380V,50Hz | 3,380V,50Hz | ||||||||
|
| Btu/h | 12,000 | 18,000 | 24,000 | 30,000 | 30,000 | 36,000 | 36,000 | 48,000 | 60,000 | |
| Capacity | kW | 3.5 | 5.4 | 7.1 | 9.2 | 9.2 | 10.5 | 10.5 | 14 | 17 | |
Cooling |
| kcal/h | 3,024 | 4,536 | 6,048 | 7,560 | 7,560 | 9,072 | 9,072 | 12,096 | 15,120 | |
| Input | W | 1,200 | 1,900 | 2,600 | 3,450 | 3,450 | 3,800 | 3,800 | 4,900 | 5,800 | |
| Rated current | A | 5.3 | 8.5 | 12.1 | 6.4 | 16.4 | 19.2 | 6.4 | 8.2 | 9.8 | |
Moisture Removal |
| L/h | 1.2 | 1.8 | 2.4 | 3 | 3 | 3.6 | 3.8 | 4.8 | 6 | |
Max. input consumption | W | 1,400 | 2,600 | 3,300 | 5,200 | 5,200 | 5,200 | 5,200 | 6,100 | 7,200 | ||
Max. current |
| A | 7.2 | 13 | 16.5 | 8.8 | 25 | 26.3 | 8.8 | 10.3 | 12.2 | |
Starting current | Type | A | 26 | 36.8 | 61 | 97 | 97 | 97 | 61 | 66 | 67 | |
|
| ROTARY | ROTARY | ROTARY | SCROLL | SCROLL | SCROLL | SCROLL | SCROLL | SCROLL | ||
| Input | W | 1,145 | 1,870 | 2,430 | 3,650 | 3,650 | 3,650 | 3,650 | 4,750 | 5,750 | |
Compressor | Rated current (RLA) | A | 5.3 | 8.75 | 11.4 | 6.58 | 17.65 | 17.65 | 6.58 | 8.22 | 9.77 | |
Locked rotor Amp (LRA) | A | 26 | 36.8 | 61 | 61 | 97 | 97 | 61 | 66 | 67 | ||
| ||||||||||||
| Thermal protector |
| Inner | Inner | Inner | Inner | Inner | Inner | Inner | Inner | Inner | |
| Capacitor | μF | 35/370μF/V | 50/370μF/V | 50/400μF/V | / | 60μF/440V | 60μF/440V | / | / | / | |
| Input | W | 104/98 | 110/104/98 | 110/104/98 | 142/134/132 | 142/134/132 | 142/134/132 | 142/134/132 | 118/108/101 | 118/108/101 | |
Indoor fan motor | Capacitor | μF | 1.5μF/450V | 2.5μF/450V | 2.5μF/450V | 3.5μF/450V | 3.5μF/450V | 3.5μF/450V | 3.5μF/450V | 2.5μF/450V | 2.5μF/450V | |
| Speed (Hi/Mid/Low) | r/min | 1,190/1,000/890 | 1,280/1,190/1,000 | 1,280/1,190/1,000 | 1,310/1,200/1,000 | 1,310/1,200/1,000 | 1,310/1,200/1,000 | 1,310/1,200/1,000 | 820/695/620 | 820/695/620 | |
| Number of rows |
| 2 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Fin spacing | mm | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 | |
Indoor coil | Fin type |
|
|
|
|
| Hydrophilic aluminum |
|
|
|
| |
| Tube outside dia.and type | mm |
|
|
|
| Ø9.53 innergroove tube |
|
|
|
| |
| Coil length height width | mm | 80425444 | 80425466 | 80425466 | 90520366 | 90520366 | 90520366 | 90520366 | 1,15025466 | 1,15025466 | |
Indoor air flow (Hi/Mid/Low) | m3/h | 600/480/400 | 800/600/500 | 1,000/900/700 | 1,200/1,000/800 | 1,400/1,200/1,000 | 1,400/1,200/1,000 | 1,400/1,200/1,000 | 2,000/1,800/1,600 | 2,000/1,800/1,600 | ||
Indoor noise level (Hi/Mid/Low) | dB(A) | 43/41/38 | 43/41/38 | 45/43/40 | 45/43/40 | 45/43/40 | 45/43/40 | 45/43/40 | 47/45/42 | 47/45/42 | ||
| Dimension (W*H*D) | mm | 995660198 | 995660198 | 995660198 | 1,285660198 | 1,285660198 | 1,285660198 | 1,285660198 | 1,670680240 | 1,670680240 | |
Indoor unit | Packing (W*H*D) | mm | 1,075744278 | 1,075744278 | 1,075744278 | 1,365744278 | 1,365744278 | 1,365744278 | 1,365744278 | 1,764760329 | 1,764760329 | |
| Net/Gross weight | kg | 30/37 | 30/37 | 30/37 | 34/42 | 34/42 | 34/42 | 34/42 | 52/62 | 52/62 | |
Outdoor fan | Input | W | 56 | 130 | 130 | 307 | 307 | 307 | 307 | 138+156 | 138+156 | |
Capacitor | μF | 2.5μF/450V | 2.5μF/450V | 3μF/450V | 10μF/450V | 10μF/450V | 10μF/450V | 10μF/450V | 3.52μF/450V | 3.52μF/450V | ||
motor | ||||||||||||
Speed | r/min | 800 | 750 | 800 | 740 | 740 | 740 | 740 | 800 | 800 | ||
| Number of rows |
| 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
| Fin spacing | mm | 1.4 | 1.7 | 1.5 | 1.7 | 1.7 | 1.7 | 1.7 | 1.8 | 1.8 | |
Outdoor coil | Fin type |
|
|
|
|
| Unhydrophilic aluminum |
|
|
|
| |
| Tube outside dia. and type | mm |
|
|
|
| Ø9.53, Innergroove tube |
|
|
|
| |
| Coil length height width | mm | 65155944 | 77566044 | 85081044 | 95591544 | 95591544 | 95591544 | 95591544 | 7151,22044 | 7151,22044 | |
Outdoor air flow |
| m3/h | 2,100 | 2,400 | 3,000 | 5,000 | 5,000 | 5,000 | 5,000 | 6,000 | 6,000 | |
Outdoor noise level |
| dB(A) | 43 | 48 | 55 | 57 | 57 | 57 | 57 | 58 | 58 | |
| Dimension (W*H*D) | mm | 760590285 | 845695335 | 895860330 | 990960360 | 990960360 | 990960360 | 990960360 | 9401,245340 | 9401,245340 | |
Outdoor unit | Packing (W*H*D) | mm | 887655355 | 970770395 | 1,043915395 | 1,1201,090435 | 1,1201,090435 | 1,1201,090435 | 1,1201,090435 | 1,0581,380435 | 1,0581,380435 | |
| Net/Gross weight | kg | 44/48 | 57/62 | 68/70 | 90/102 | 90/102 | 90/102 | 90/102 | 112/127 | 112/127 | |
Refrigerant type/Quantity | g | |||||||||||
Design pressure (high side/low side) | MPa | 4.2/2.5 | 4.2/2.5 | 4.2/2.5 | 4.2/2.5 | 4.2/2.5 | 4.2/2.5 | 4.2/2.5 | 4.2/2.5 | 4.2/2.5 | ||
Refrigerant | Liquid side | mm (inch) | 6.35 (1/4) | 6.35 (1/4) | 9.53 (3/8) | 12.7 (1/2) | 12.7 (1/2) | 12.7 (1/2) | 12.7 (1/2) | 12.7 (1/2) | 12.7 (1/2) | |
Gas side | mm (inch) | 12.7 (1/2) | 12.7 (1/2) | 16 (5/8) | 19 (3/4) | 19 (3/4) | 19 (3/4) | 19 (3/4) | 19 (3/4) | 19 (3/4) | ||
piping | Max. pipe length | m | 25 | 25 | 30 | 30 | 30 | 30 | 30 | 50 | 50 | |
| Max. difference in level | m | 15 | 15 | 15 | 20 | 20 | 20 | 20 | 30 | 30 | |
Operation temp |
| ºC | 17~30 | 17~30 | 17~30 | 17~30 | 17~30 | 17~30 | 17~30 | 17~30 | 17~30 | |
Ambient temp |
| ºC | 18~45 | 18~45 | 18~45 | 18~45 | 18~45 | 18~45 | 18~45 | 18~45 | 18~45 | |
Qty’per 20’& 40’Fcl |
| Pieces | 63/138/155 | 49/104/126 | 44/94/101 | 27/55/62 | 27/55/62 | 27/55/62 | 27/55/62 | 25/50/54 | 25/50/54 |