Installation
The oven must be installed according to the instructions supplied.
This oven must be installed by qualified personnel to the relevant British Standards.
Technical Data
DIMENSIONS | Height | 580 mm. |
OF RECESS | Width | |
| Depth | 550 mm. |
|
|
|
DIMENSIONS | Height | 320 mm. |
OF THE | Width | 420 mm. |
OVEN CAVITY | Depth | 390 mm. |
| Oven capacity 53.2 litres | |
|
|
|
Heating elements rating (230 V)
Ovenelement | 1.8 kW |
Top element | 0.8 kW |
Bottom element | 1.0 kW |
Convection element | 2.0 kW |
Grill element | 1.75 kW |
Double Grill element | 2.55 kW |
ConvectionFan | 30 W |
OvenLight | 25 W |
Cooling Fan | 25 W |
Total Rating | 2.6 kW |
Electrical Connection
The oven is designed to be connected to
The oven has an easily accessible terminal block which is marked as follows:
Letter L | - | Liveterminal | |||||||
Letter N | - | Neutral terminal | |||||||
|
|
|
|
|
|
|
| - | Earth terminal |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
THIS OVEN MUST BE EARTHED
Model BMS 641 is provided with a a type
Model BST 6 is supplied without connection cable. A suitable one must be fitted to the appliance, according to the following type list:
—H07
—H05
—H07
—H05
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
The manufacturer disclaims any responsibility should these safety measures not be carried out.
20