Zanussi ZBS 963 Installation, Electrical Connection, For Uk use only, For Europe use only, Fuse

Models: ZBS 963

1 24
Download 24 pages 6.3 Kb
Page 22
Image 22
Installation

Installation

The oven must be installed according to the

This oven must be installed by qualified

instructions supplied.

 

personnel to the relevant British Standards.

Technical Data

 

Heating elements rating

 

Dimensions of recess

 

Oven element

1,880 W

 

Top element

835 W

Height

580 mm.

Bottom element

1,045 W

Width

560 mm.

 

 

Depth

550 mm.

Convection element

2,090 W

 

 

Grill element

1,795 W

Dimensions of the oven cavity

 

Double Grill element

2,665 W

Height

335 mm.

Pizza Oven Function

3,135 W

Width

395 mm.

Convection Fan

30 W

Depth

400 mm.

Oven Light

15 W

Oven capacity

53 litres

Cooling Fan

25 W

 

 

 

 

Total Rating

3,200 W

 

 

Supply voltage (50 Hz)

230-240 V

Electrical Connection

The oven is designed to be connected to 230-240V (50Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical DataTHIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For Uk use only

ConnectionMin. sizeCable / flexFuse

via

Cable/flextype

 

 

 

 

 

• Cooker

2.5 mm2

PVC/PVC

20 A

Control

 

twin and

 

Circuit

 

earth

 

 

 

 

 

For Europe use only

Min. size Cable/flexCable / flex type

Fuse

 

 

 

2.5 mm2

H07 RN-F, H05 RN-F,

15 A

 

H05 RR-F, H05 VV-F,

 

 

H05 V2V2-F (T90),

 

 

H05 BB-F

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperatu- re of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

The manufacturer disclaims any responsibility should these safety measures not be carried out.

22

Page 22
Image 22
Zanussi ZBS 963 Installation, Electrical Connection, For Uk use only, For Europe use only, Technical Data, Min. size, Fuse