Zanussi ZCG 611 Instructions for the Installer, Important Safety Requirements, Technical Data

Models: ZCG 611

1 24
Download 24 pages 51.54 Kb
Page 17
Image 17

Instructions for the Installer

Technical Data

 

 

 

 

 

Hob

 

 

 

 

 

 

 

Appliance Class 2 sub class 1 and Class 1

 

 

 

 

Rear left burner (semi-rapid)

 

 

2,000 W

APPLIANCE CATEGORY:

 

II 2H3+

 

Front left burner (rapid)

 

 

3,000 W

APPLIANCE GAS SUPPLY: Natural Gas G20 20mbar

 

Rear right burner (semi-rapid)

 

 

2,000 W

 

 

 

 

 

 

 

 

Front right burner (auxiliary)

 

 

1,000 W

Dimensions

 

 

 

 

 

Oven

 

 

 

 

 

 

Height

 

 

 

 

900 mm

 

 

 

 

 

 

 

 

 

 

 

 

Electric Grill

 

 

 

 

 

1,830 W

Depth

 

 

 

 

600 mm

 

 

 

 

 

 

 

 

 

 

 

Gas Oven burner

 

 

 

 

2,700 W

Width

 

 

 

 

600 mm

 

 

 

 

 

 

 

 

 

 

Oven light

 

 

 

 

 

15 W

Oven Capacity

 

1.7 Cu. ft

 

 

 

 

 

 

 

 

Total Rating

 

 

 

 

 

1,845 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply voltage (50 Hz)

 

 

230-240 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

 

OVEN

 

TYPE OF

CHARACTERISTICS

 

 

 

(large)

(medium)

(small)

 

 

 

 

GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

MAX

 

MIN

MAX

 

MIN

MAX

MIN

 

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER (kW)

 

3.0

 

0.65

2.0

 

0.45

1.0

0.33

 

2.7

1.1

 

NATURAL

VALUE =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS

37.78 MJ/m3

 

NOMINALFLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

20 mbar

Ws - 50.7 MJ/ m3

 

RATE (m3/h)

 

0.286

 

0.057

0.190

 

0.038

0.095

0.028

 

0.257

0.105

 

 

 

 

NOZZLEREFERENCE

 

119

 

Adjust.

96

 

Adjust.

70

Adjust.

 

114

Adjust.

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINALTHERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER (kW)

 

2.8

 

0.65

2.0

 

0.45

1.0

0.33

 

2.7

1.1

 

LPG GAS

VALUE =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-30/37

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

49.92 MJ/Kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mbar

 

RATE (g/h)

 

202

 

43.5

144

 

29

72

21,5

 

195

79

 

 

 

 

 

 

 

 

 

 

 

NOZZLEREFERENCE

 

86

 

40

71

 

32

50

28

 

83

55

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Important Safety Requirements

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations (current addition) and the I.E.E. Wiring Regulations. Detailed recommendations are contained in the following British Standard Codes of Practice - B.S. 6172, B.S. 5440: Part 2 and B.S. 6891: Current Editions.

Provision for Ventilation

The room containing the cooker should have an air supply in accordance with B.S. 5440: Part 2: Current Editions.

The following requirements for ventilation must be met.

The cooker should not be installed in a bed sitting room with a volume of less than 20m3, if it is installed in a room of volume less 5m3 an air vent of effective area of 110cm2 is required; if it is installed in a room of volume between 5m3 and 10m3, an air vent of effective area 50cm2 is required, while if the volume exceeds 11m3 no air vent is required. However, if the room has a door which opens directly to the outside, no air vent is required even when the volume is between 5m3 and 11m3.

If there are other fuel burning appliances in the same room, B.S. 5440: Part. 2: Current Editions should be consulted to determine the requisite air vent requirements.

17

Page 17
Image 17