Instructions for the Installer
Technical Data
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY:II 2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 20mbar
Dimensions
Height | 900 mm |
Depth | 600 mm |
Width | 600 mm |
Oven Capacity | 1.8 Cu. ft |
Hob
Rear right burner | 2,000 W |
Front right burner (auxiliary) | 1,000 W |
Rear left burner | 2,000 W |
Front left burner | 3,500 W |
Oven
Top heating element | 835 W |
Bottom heating element | 1,045 W |
Ovenelement | 1,880 W |
Grill Element | 1,830 W |
Convection heating element | 2,090 W |
Convection fan | 30 W |
Oven light | 15 W |
Total rating | 2,135 W |
Supply voltage (50 Hz) |
TYPE OF GAS | CHARACTERISTICS |
| BURNER | AUXILIARY | |||||||
|
| (large) | (medium) | (small) | |||||||
|
|
|
|
|
|
|
| ||||
| POSITION | MAX | MIN | MAX | MIN | MAX | MIN | ||||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 |
|
|
|
|
|
|
|
|
|
NATURAL GAS |
| VALUE = 37.78 MJ/m | Ws - 50.7 MJ/ m3 | NOMINAL THERMAL |
|
|
|
|
|
| |
20 mbar | POWER kW | 3.5 | 1.2 | 2.0 | 0.45 | 1.0 | 0.33 | ||||
NOMINAL FLOW |
|
|
|
|
|
| |||||
RATE | m3/h | 0.333 | 0.114 | 0.190 | 0.043 | 0.095 | 0.031 | ||||
NOZZLEREFERENCE | 136 | Adjust. | 96 | Adjust. | 70 | Adjust. | |||||
| 1/100 mm |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
| VALUE = 49.92 MJ/Kg | NOMINAL THERMAL |
|
|
|
|
|
| |||
LPG GAS | POWER kW | 3.5 | 1.2 | 2.0 | 0.45 | 1.0 | 0.33 | ||||
NOMINAL FLOW |
|
|
|
|
|
| |||||
RATE | g/h | 252 | 86.5 | 144 | 32 | 72 | 24 | ||||
NOZZLEREFERENCE | 93 | 56 | 71 | 32 | 50 | 28 | |||||
| 1/100 mm |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
Important Safety Requirements
This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations (current addition) and the I.E.E. Wiring Regulations. Detailed recommendations are contained in the following British Standard Codes of Practice - B.S. 6172, B.S. 5440: Part 2 and B.S. 6891: Current Editions.
Provision for Ventilation
The room containing the cooker should have an air supply in accordance with B.S. 5440: Part 2: Current Editions. The following requirements for ventilation must be met. The cooker should not be installed in a bed sitting room with a volume of less than 20m3, if it is installed in a room of volume less 5m3 an air vent of effective area of 110cm2 is required; if it is installed in a room of volume between 5m3 and 10m3, an air vent of effective area 50cm2 is required, while if the volume exceeds 11m3 no air vent is required. However, if the room has a door which opens directly to the outside, no air vent is required even when the volume is between 5m3 and 11m3.
19