Zanussi ZCM ID manual Connecting to GAS, Connection to the Electricity Supply

Models: ZCM ID

1 56
Download 56 pages 16.56 Kb
Page 49
Image 49

4. CONNECTING TO GAS

50

100

This appliance is designed to be installed with an

 

 

appliance flexible connection only. Supply piping should

 

 

not be less that R³/8. Connection is made to the Rc ½ (½"

 

 

B.S.P.) female threaded entry pipe located just below the

 

 

hotplate level on the rear left hand side of the appliance.

 

 

NOTE: ONLY LIQUID SEALANTS TO BE USED WHEN

 

 

INLET GAS PIPE IS FITTED TO SHUT OFF VALVE

 

 

I.E.: DO NOT USE P.T.F.E. SEALANT TAPE. Check for

 

 

gas soundness after connecting to the gas supply.

 

 

The gas bayonet connector must be fitted in the shaded

850

 

area indicated in Fig.3. Take into account that it must be

 

 

 

possible to pull the appliance forward sufficiently. The

 

 

hose must not get caught on the stability bracket.

 

 

IMPORTANT: FLEXIBLE TUBING USED MUST

 

 

COMPLY WITH BS. 669 CURRENT EDITION.

 

 

 

250

 

All dimensions in mm

5. CONNECTION TO THE ELECTRICITY SUPPLY

WARNING: THIS APPLIANCE MUST BE EARTHED.

DO NOT EARTH THIS APPLIANCE TO THE GAS

SUPPLY PIPING.

This appliance must be connected to a 230V A.C. 50Hz supply. It is supplied with 2 metres of 15 amp 3 core cable incorporating a moulded 13 amp plug , fitted with a 13 amp fuse, which can be plugged directly into the nearest suitable socket. If this is not long enough, the supply cable can be either:-

(i)Replaced totally by a longer cable at least 1.5mm² nominal cross sectional area (30/0.25mm).

(ii)Extended by using a B.E.A.B. approved 3-way sealed flex connector with integral flex clamps.

IF THE MOULDED PLUG IS CUT FROM THE CABLE

FOR ANY REASON, IT MUST BE DESTROYED OR

DISPOSED OF SAFELY, AS THE PROTRUDING

WIRES WILL BE AN ELECTRIC SHOCK HAZARD.

Fig.3

450 700

Fig.4

If any other type of plug is used it should incorporate a 13 amp fuse in either the plug or adapter or at the distribution board.

If the cable has to be threaded through small apertures in cabinets etc., it may be disconnected from the appliance, then re-connected to as shown in Fig.4.

DO NOT EXTEND THE CABLE USING PLASTIC OR CERAMIC CONNECTION TERMINAL BLOCKS AND/OR INSULATION TAPE.

ALL EXTERNAL WIRING BETWEEN THE APPLIANCE AND THE ELECTRICAL SUPPLY SHALL COMPLY WITH I.E.E. WIRING REGULATIONS.

49

Page 49
Image 49
Zanussi ZCM ID manual Connecting to GAS, Connection to the Electricity Supply