Adjusting the level of conductivity

Water contains, a variable quantity of limestone and mineral salts of which quantities vary according to geographical locations thus varying its conductivity values.

Relevant variations of the conductivity of the water compared to those prefixed by the factory could slightly influence the residual humidity of the laundry at the end of the cycle.

Your dryer allows you to regulate the sensitivity of the drying sensor based on conductivity values of the water by using the following procedure.

Display

Conductivity degree

Approximative value

 

 

 

 

(μS/cm)

 

 

 

 

 

C 0

 

 

Low

< 300

 

 

 

 

 

C 0

 

 

Medium

300 - 600

 

 

 

 

 

 

 

C 0

 

 

High

> 600

 

 

 

 

 

 

 

 

Normally, the appliance is factory-set to the highest level; however, certain models may be configured differently.

Procedure:

Turn the programme selector dial to switch on the appliance

In selection mode press simultaneously the buttons 3 and 6 until «C0» appears on the digits.

EXTRA

 

RESET/

 

COTTON

 

 

 

 

 

 

 

Cooling

OFF

Extra dry

 

 

 

 

1.25

 

 

PROGRAMMES

 

 

 

 

 

 

 

Drying

Easy iron

 

Ready to wear

 

 

 

 

 

Cooling

30 min

 

 

Store dry

 

 

 

 

 

 

End

 

 

 

 

 

 

 

 

 

60 min

 

 

Slightly damp

 

 

 

 

 

 

 

 

 

 

 

 

Door

No

Quick

Low

Delay

Start/

 

90 min

 

 

Iron dry

 

Buzzer

Dry

Temperature

Start

Pause

 

 

 

 

1

2

3

4

5

6

Full Tank

 

 

 

 

 

Baby dry

 

Wring dry

 

 

 

Iron dry

Store

Extra dry

 

 

 

 

 

 

 

 

 

 

dry

SYNTHETIC

 

 

 

 

 

 

 

Memorizing the new setting:

Simultaneously press down the buttons 3 and 6 until the previous drying cycle time appears again on the display and the buzzer sounds.

Adjusting the level of conductivity:

Press the button 5 sequentially: the level of conductivity is indicated by the lighting of the horizontal hyphens.

 

 

 

 

 

Drying

 

 

 

 

 

Cooling

 

 

 

 

 

End

No

Quick

Low

Delay

Start/

 

Buzzer

Dry

Temperature

Start

Pause

 

2

3

4

5

6

Full Tank

 