Hints for Test Institutes

156999480en.qxp 3/2/2006 8:11 AM Pagina 21

Hints for Test Institutes

Testing in accordance with EN 60704 must be carried out with appliance fully loaded and using the test programme (see "Consumption values").

Test in accordance with EN 50242 must be carried out when the salt container and rinse aid dispenser have been filled with salt and rinse aid respectively and using the test programme (see "Consumption values").

 

 

 

 

 

 

 

 

 

Full load:

 

 

 

 

 

 

 

 

 

12 standard place settings

Amount of detergent required:

5 g + 25 g (Type B)

 

 

 

 

 

 

 

 

 

 

Rinse aid setting:

position 4 (Type III)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Upper basket

cup racks:

 

 

position A

Lower basket

 

 

 

 

Cutlery basket

Installation

Installation WARNING!

Any electrical and/or plumbing work required to install this appliance should be carried out by a qualified electrician and/or plumber or competent person.

Water connection

Water connection WARNING!

The dishwasher must not be connected to open water appliances or instantaneous water heaters. This dishwasher must be fed with cold water.

WARNING!

Only use, for connection to the water mains, new hose-set; old hose-set must not be reused.