Electrical connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

WARNING: THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this safety measure not be observed.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance’s rating plate. The rating plate is located at the top of the rim of the open door.

 

Mod

 

Prod. No

P0042

Ser. No

 

The appliance is supplied with a 13amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved (BS1363/A) fuse must be used.

Should the plug need to be replaced for any reason, proceed as described below.

The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow

- Earth

Blue

 

 

- Neutral

Brown

 

 

- Live

GREEN & YELLOW

 

 

E

 

 

 

 

13A

 

 

N

L

 

 

 

 

 

 

BROWN

 

BLUE

 

 

 

P1041

 

CORD CLAMP

 

 

 

 

The wire coloured green and yellow must be connected to the terminal marked with the letter «E» or by the

earth symbol

or coloured green and yellow.

The wire coloured blue must be connected to the terminal «N» or coloured black.

The wire coloured brown must be connected to the terminal marked «L» or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

WARNING:

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of safely.

Should the appliance power supply cable neeed to be replaced, this should be carried out by our Service Force Centre.

Note

When the appliance is installed the power supply cable must be accessible.

Permanent connection

In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at any point.

28

Page 28
Image 28
Zanussi ZJ 1217 manual Electrical connection, Permanent connection