Zanussi ZKC5030 Installation instructions, Connecting to the electricity supply, 685 min, 40 min

Models: ZKC5030

1 36
Download 36 pages 22.71 Kb
Page 30
Image 30
Installation instructions

Installation instructions

This appliance must be earthed WARNING!

This appliance must be earthed

If your appliance has been damaged in transit, contact your supplier immediately. Do not attempt to install it.

Your appliance left the factory fully packaged to protect it from damage. If it is delivered without packaging and damage has occurred, the manufacturer cannot accept responsibility. Contact your supplier for advice.

Once the packaging has been removed the appliance should only be moved by hand. Do not use a sack barrow or any other aid to lift the appliance as damage may occur.

To move the appliance, open the oven door and lift the appliance by holding inside the top of the compartment.

This is a type X appliance, which means it is freestanding and can be fitted with cabinets on one or both sides.

685 min

40 min

Sidewalls, which are above hob level, should be protected by heat resistant non-combustible material and must not be nearer than 40mm to the hob side.

A nominal air gap of 2mm at either side of the appliance is required to enable the appliance to be moved into position.

30

Always ensure an air gap is maintained at hotplate level. Tiles or other forms of deep wall covering should not obscure this gap.

Overhanging surfaces or a cooker hood should be a minimum of 685mm above the hob.

It is important to ensure that the appliance is level after installation. Levelling feet are fitted to the appliance to accommodate uneven floors.

Connecting to the electricity supply

685 min WARNING!

This appliance must be earthed. Do not earth this appliance to gas supply piping. Connect to 230 - 240V AC supply only.

Connection to the electricity supply must be carried out by a qualified electrician/competent person.

The electrical connection should be made using a double pole isolating switch (cooker socket) with at least 3mm contact separation in all poles. The cable must have conductors of sufficiently high cross-sectional area to prevent overheating and deterioration.

We recommend you use a new length of 6mm2 twin core earthed cable to ensure your safety.