Zanussi ZKG5020 The battery, Pressure testing, Close the lid of the battery holder, 20mm, 100mm

Models: ZKG5020

1 36
Download 36 pages 35 Kb
Page 30
Image 30
20mm

 

20mm

(B)

Stability

478mm

bracket

 

 

100mm

250mm

(A)

3.Draw a line 100mm from the front edge of the feet and remove appliance from its position. Mark off dimension 'B' back from this line on the centre line of the bracket to locate the front edge of the lower bracket. Fix lower bracket (with two fixing holes) to the floor then measure the height from floor level to engagement edge on back of appliance, dimension 'C'.

Stability bracket

(C)

30

Assemble upper bracket to lower bracket so that the underside of bracket is dimension 'C' + 3mm above floor level.

Reposition appliance and check that top bracket engages into appliance back as shown.

The battery

1.The battery is located on the left hand side of the front plinth.

2.To gain assess to the battery, open the main oven door and lift up the battery holder lid.

3.Fit the new battery ensuring (+) terminal is next to the (+) sign on the battery.

4. Close the lid of the battery holder.

Pressure testing

1.The oven injector is used as a pressure test point. Remove the oven furniture.

Remove oven burner box retaining clips (one spring clip from each side) and remove box front cover. Replace one clip back into the right hand side of the burner box.

Remove oven burner by removing the spring clip from the right hand side of the oven burner and slide burner off injector, whilst easing it forward and taking care not to strain the F.S.D. phial.

2.Connect the pressure gauge to the oven injector.

3.Check the supply pressure by turning the thermostat on and one hotplate tap full on

Page 30
Image 30
Zanussi ZKG5020 Pressure testing, The battery is located on the left hand side of the front plinth, Stability bracket