•Curtains must not be fitted immediately behind the appliance or within 150mm of the sides of the hotplate. If fitted next to or between two base units a minimum space of 1mm must be left between each unit and the sides of the appliance. The hotplate must be set to a minimum of 7mm above the adjacent units. (Note: The leveling feet fitted to the appliance will achieve a nominal height of 907mm
Leveling the appliance
•Adjustment to suit floor conditions or height is obtained by rotating clockwise or anti clockwise the feet at the front and rear of the appliance. A spirit level should be placed on one of the shelves to confirm the appliance is correctly leveled.
Connecting to gas supply
•This appliance is designed to be installed with an appliance flexible connection only.
•Supply piping should not be less than R3/8. Connection is made to the Rc ½ (½” B.S.P.) female threaded entry pipe located just below the hob level on the rear left hand side of the appliance.
IMPORTANT!
ONLY LIQUID SEALANTS TO BE USED WHEN INLET GAS PIPE IS FITTED I.E.: DO NOT USE P.T.F.E. SEALANT TAPE.
•Carry out a gas tightness test after connecting to the gas supply.
•The gas bayonet connector must be fitted in the shaded area indicated.
| 650mm |
250mm | 400mm |
|
200mm
•Take into account that it must be possible to pull the appliance forward sufficiently. Ensure the hose does not become trapped when pushing the appliance into position.
IMPORTANT!
FLEXIBLE TUBING USED MUST COMPLY WITH BS.669 CURRENT EDITION.
Fitting the stability bracket
•It is recommended that if the appliance is to be installed with a flexible supply pipe, a stability bracket be fitted and is available from your supplier (see Important Safety Requirements). These instructions should be read in conjunction with any leaflet packed with the stability bracket.
1.Place the appliance in its intended position and level appliance.
2.Mark off 250mm from the left hand side of the appliance as shown in dimension 'A'. This is the centre line of the fixing bracket.
29