Connections

Minimum space above hob level

Connections

Gas connection

Electrical connection

Ignition

787mm (If a cooker hood is fitted refer to the cooker- hood installation instructions)

Rear left hand side of appliance at hob level. Rc ½" ( ½

"B.S.P. female) None

Battery 1.5 Volt AA size

GAS CONSUMPTION TABLE

 

 

LPG

 

NG

 

 

GB: I3+

 

 

 

 

GB: I2H

 

 

 

IE: I3+

 

 

 

 

 

 

LARGE BURNER

 

 

 

 

 

INJECTOR

 

85

 

 

115

NOMINAL RATING (KW)

 

3

 

 

3

CONSUMPTION IN 1h

 

218.3 gr/h

 

 

285.7 lt/h

MEDIUM BURNER

 

 

 

 

 

INJECTOR

 

65

 

 

97

NOMINAL RATING (KW)

 

1.75

 

 

1.75

CONSUMPTION IN 1h

 

127.25 gr/h

 

 

166.7 lt/h

SMALL BURNER

 

 

 

 

 

INJECTOR

 

50

 

 

72

NOMINAL RATING (KW)

 

1

 

 

1

CONSUMPTION IN 1h

 

72.7 gr/h

 

 

95.3 lt/h

MAIN OVEN BURNER

 

 

 

 

 

INJECTOR

 

98

 

 

115

NOMINAL RATING (KW)

 

2.4

 

 

2.4

CONSUMPTION IN 1h

 

174.5 gr/h

 

 

228.6 lt/h

TOP OVEN BURNER

 

 

 

 

 

INJECTOR

 

98

 

 

115

NOMINAL RATING (KW)

 

2.4

 

 

2.4

CONSUMPTION IN 1h

 

174.5 gr/h

 

 

228.6 lt/h

GRILL BURNER

 

 

 

 

 

INJECTOR

 

68

 

 

110

 

 

 

 

 

 