6.If your printer includes a media dancer assembly (1), thread the media under the media dancer assembly roller. For all printers, thread the media under the media guide roller (2) and then the upper media sensor (3).

Important • Make sure that you thread the media under these components. If you thread the media over them, the media obstructs the ribbon sensor and causes a false

RIBBON OUT error.

3

2

1

7.Push the media forward until it passes under the printhead assembly (1), under the snap plate (2), and then over the platen roller (3).

1

2

3