External Control Device Setup

Set ID

- Use this function to specify a TV ID number. - Refer to ‘Real Data Mapping 1’. See page 35.

1. Press the MENU button and then use D / E button to select the SPECIAL menu.

2. Press the G button and then use D / E button to select Set ID.

3. Press the G button and then use F / G button to adjust Set ID to choose the desired TV ID number. The adjustment range of Set ID is 1 ~ 99.

4. Press the ENTER button to save.

Communication Parameters

• Baud rate : 115200 bps (UART)

• Stop bit : 1 bit

• Data length : 8 bits

• Communication code : ASCII code

• Parity : None

 

SPECIALI

Language

Key lock

ISM Method

Low power

Set ID

G

Caption / Text

Captions

OSD Rotate

MENU Prev.

1

* Use a crossed (reverse) cable.

Command Reference List

 

COMMAND 1 COMMAND 2

DATA

 

 

 

 

(Hexadecimal)

 

 

 

 

 

01. Power

k

a

0

~ 1

02.

Input Select

k

b

0

~ 6

03. Aspect Ratio

k

c

0

~ 3

04. Screen Mute

k

d

0

~ 1

05. Volume Mute

k

e

0

~ 1

06.

Volume Control

k

f

0

~ 64

07.

Contrast

k

g

0

~ 64

08.

Brightness

k

h

0

~ 64

09.

Color

k

i

0

~ 64

10. Tint

k

j

0

~ 64

11. Sharpness

k

k

0

~ 64

12. OSD Select

k

l

0

~ 1

13.

Remote Control Lock Mode

k

m

0

~ 1

14. PIP/DW

k

n

0

~ 3

15.

PIP Aspect Ratio

k

o

0

~ 1

16.

Split Zoom

k

p

21 ~99

17.

PIP Position

k

q

0

~ 3

18. Treble

k

r

0

~ 64

19. Bass

k

s

0

~ 64

20.

Balance

k

t

0

~ 64

21.

Color Temperature

k

u

0

~ 3

22. Red Adjustment

k

v

0

~ C8

23. Green Adjustment

k

w

0

~ C8

24.

Blue Adjustment

k

$

0

~ C8

25.

PIP Input Source

k

y

0

~ 6

26. Abnormal State

k

z

0

~ a

27. ISM Method

j

p

0

~ 3

28. Low Power

j

q

0

~ 1

 

 

 

 

 

 

29.

Orbiter Time Setting

j

r

1

~ FE

30.

Orbiter Pixel Setting

j

s

0

~9

31.

Picture Size Setting

j

t

0

~64

 

for Double Window mode

 

 

 

 

32. Auto Configure

j

u

1

 

Menu doesn’t display on screen when setting the 4, 12, 13, and 26 ~ 32.

Transmission / Receiving Protocol

Transmission

[Command1][Command2][ ][Set ID][ ][Data][Cr]

*[Command 1]: First command to control the TV. (j or k)

*[Command 2]: Second command to control the TV.

*[Set ID]: You can adjust the set ID to choose desired TV ID number in Special menu. Adjustment range is 1 ~

99.When selecting Set ID ‘0’, every connected the TV is controlled. Set ID is indicated as decimal (1~99) on menu and as Hexa decimal (0x0~0x63) on transmission/receiving protocol.

*[DATA]: To transmit command data.

Transmit ‘FF’ data to read status of command.

*[Cr]: Carriage Return ASCII code ‘0x0D’

* [ ]: ASCII code ‘space (0x20)’

OK Acknowledgement

[Command2][ ][Set ID][ ][OK][Data][x]

*The TV transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of the PC com- puter.

Error Acknowledgement

[Command2][ ][Set ID][ ][NG][Data][x]

*The TV transmits ACK (acknowledgement) based on this format when receiving abnormal data from non-viable functions or communication errors.

Data 1: Illegal Code

2:Not supported function

3:Wait more time

34 Plasma TV

Page 34
Image 34
Zenith P42W34H manual Set ID, Communication Parameters, Command Reference List, Transmission / Receiving Protocol