External Control Device Setup

25. PIP Input Select (Command2:y)

GTo select input source for sub picture in PIP mode.

Transmission

[k][y][ ][Set ID][ ][Data][Cr]

Data 0

: RGB

4

: DVI

1

: Component

5

: TV

2

: Video

6

: Video (Exp.)

3

: S-Video

 

 

Acknowledgement

[y][ ][Set ID][ ][OK][Data][x]

26. Abnormal State (Command2:z)

G To recognize an abnormal state.

Transmission

[k][z][ ][Set ID][ ][FF][Cr]

Data FF:Read

Acknowledgement

[z][ ][Set ID][ ][OK][Data][x]

Data 0: Normal (Power on and signal exist)

1:No signal (Power on)

2:Turn the monitor off by remote control

3:Turn the monitor off by sleep time function

4:Turn the monitor off by RS-232C function

5:5V down

6:AC down

7:Turn the monitor off by Fan Alarm function

8:Turn the monitor off by off time function

9:Turn the monitor off by auto off function a: Turn the monitor off by AV board detect

27.ISM Method (Command2:p)

G To avoid having a fixed image remain on screen.

Transmission

[j][p][ ][Set ID][ ][Data][Cr]

Data

0: Normal

2: Orbiter

 

1: White wash

3: Inversion

Acknowledgement

 

 

 

 

 

 

[p][

][Set ID][ ][OK][Data][x]

 

 

 

 

 

 

28. Low Power (Command2:q)

G To control the low power function on/off.

Transmission

[j][q][ ][Set ID][ ][Data][Cr]

Data 0: Low power off 1: Low power on

Acknowledgement

[q][ ][Set ID][ ][OK][Data][x]

29. Orbiter Time Setting (Command2:r)

G To adjust orbiter operation time term.

Transmission

[j][r][ ][Set ID][ ][Data][Cr]

Data Min: 1 ~ Max: FE

Acknowledgement

[r][ ][Set ID][ ][OK][Data][x]

30. Orbiter Pixel Setting (Command2:s)

G To adjust pixel number in orbiter function.

Transmission

[j][s][ ][Set ID][ ][Data][Cr]

Data Min: 0 ~ Max: 9

Acknowledgement

[s][ ][Set ID][ ][OK][Data][x]

31.Picture Size Setting for Double Window mode (Command2:t)

G To adjust main window size in Double Window mode.

Transmission

[j][t][ ][Set ID][ ][Data][Cr]

Data Min: 0 ~ Max: 64

Refer to ‘Real data mapping1’. See page 35. Acknowledgement

[t][ ][Set ID][ ][OK][Data][x]

32. Auto Configure (Command2:u)

G To adjust picture position and minimize image shaking automatically. It works only in RGB (PC) mode.

Transmission

[j][u][ ][Set ID][ ][Data][Cr]

Data 1: To set

Acknowledgement

[u][ ][Set ID][ ][OK][Data][x]

38 Plasma TV

Page 38
Image 38
Zenith P42W34H manual PIP Input Select Command2y, Abnormal State Command2z, ISM Method Command2p, Low Power Command2q