Blower Preparation

www.zephyronline.com

CBE-1000 EXTERNAL OR PBN-1000A IN-LINE BLOWER INSTALLATION

Installation – Remote

1.Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10” round duct work to 10” round adapter.

3.Place cap over threaded end of external blower wiring and secure by turning clockwise.

2.Install threaded end of external blower wiring through external blower wiring knock out located inside the hood.

4.Connect 6 pin male connector from external blower wiring to 6 pin female connector on control board wire inside hood. Secure green ground wire from external blower wiring to ground screw on hood.

REMOTE BLOWER: WIRING DIAGRAM

Remote Blower

White (common)

Black (high)

Wiring Box

Blue (med)

(hood)

Red (low)

 

Green (ground)

Junction Box

(Remote Blower)

NOTE: For instructions on mounting the external and in-line blowers, please refer to the manual included

in the blower packaging or on our website: www.zephyronline.com