Zephyr AK7848ASX Installation - Ducting Calculation Sheet, Subtotal column 1 =, Total ductwork

Models: AK7836ASX AK7848ASX AK7842ASX

1 19
Download 19 pages 51.82 Kb
Page 7
Image 7
Subtotal column 1 =

Duct pieces

Equivalent number

 

Total

 

length x used

=

 

3-1/ 4” x 10”

1 Ft.

x (

)

=

Ft.

Rect.,

 

 

 

 

 

straight

 

 

 

 

 

6” Round,

1 Ft.

x (

)

=

Ft.

straight

 

 

 

 

 

7”-10” Round,

1 Ft.

x (

)

=

Ft.

straight

 

 

 

 

 

3-1/ 4” x 10”

15 Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

elbow

 

 

 

 

 

3-1/ 4” x 10”

9 Ft.

x (

)

=

Ft.

Rect.450

 

 

 

 

 

elbow

 

 

 

 

 

3-1/ 4” x 10”

24 Ft.

x (

)

=

Ft.

Rect.900

 

 

 

 

 

flat elbow

 

 

 

 

 

3-1/ 4” x 10”

30 Ft.

x (

)

=

Ft.

Rect.

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

3-1/ 4” x 10”

5 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

3-1/ 4” x 10”

20 Ft.

x (

)

=

Ft.

Rect.to

 

 

 

 

 

6” round

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

6” Round,

15 Ft.

x (

)

=

Ft.

900 elbow

 

 

 

 

 

6” Round,

9 Ft.

x (

)

=

Ft.

450 elbow

 

 

 

 

 

 

Subtotal column 1 =

Ft.

Duct pieces

Equivalent number

 

Total

 

length x used

=

 

6” Round

30 Ft.

x (

)

=

Ft.

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

6” Round,

30 Ft.

x (

)

=

Ft.

roof cap

 

 

 

 

 

6” round to

1 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

6” round to

16 Ft.

x (

)

=

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

900 elbow

 

 

 

 

 

7” - 10”

15 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

900 elbow

 

 

 

 

 

7” - 10”

9 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

450 elbow

 

 

 

 

 

7” - 10”

30 Ft.

x (

)

=

Ft.

Round

 

 

 

 

 

wall cap

 

 

 

 

 

with damper

 

 

 

 

 

7” - 10”

30 Ft.

x (

)

=

Ft.

Round,

 

 

 

 

 

roof cap

 

 

 

 

 

7” round to

8 Ft.

x (

)

=

Ft.

31/ 4” x 10” rect. transition

7” round to

23 Ft.

x (

) =

 

Ft.

3-1/ 4” x 10”

 

 

 

 

 

rect.

 

 

 

 

 

transition

 

 

 

 

 

 

 

 

 

 

900 elbow

 

 

 

 

 

 

 

 

Subtotal column 2 =

 

Ft.

Subtotal column 1 =

 

 

 

Ft.

Total ductwork

=

 

 

 

Ft.

Installation – Ducting Calculation Sheet

Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet.

5

Page 7
Image 7
Zephyr AK7848ASX, AK7842ASX, AK7836ASX manual Installation - Ducting Calculation Sheet, Subtotal column 1 =, Total ductwork