Installation - Internal Blower

www.zephyronline.com

Installation - Internal Blower

Manual background The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fire and electric shock, install this range- hood only with internal blower models MT-020 provided with the kit cod CBI-600A.

For external and in-line blower prepa- ration please turn to page 18.

1.Remove the 6” round metal knockout plate from the blower plate by using a flat head screwdriver. See.Fig.1

2. Remove the (6) screws securing the blower plate to the blower housing and remove blower plate. See. Fig.2

3.Place the 6" metallic flange on the blower's air outlet Fig.3A.(the flange

may already be pre-installed). Install internal blower into blower plate and secure using (4) screws included with the blower. See Fig.3B

4. Secure capacitor box connected to the provided cable to the blower plate using (2 type B) screws inclu- ded with the blower. See.Fig.4

5. Secure Green/Yellow ground wire connected to the cable to the provi- ded capacitor to blower plate.Fig.5 (type A)