8.Secure cover to junction box using (2) screws.

6. Insert the 6 pin female molex connector into the junction box. See Fig. 6A. Secure remote blower junction box to top of blower housing using (2) screws. See Fig. 6B

7. Feed remote blower wire harness through remote blower junction box cover and Connect the wires with those inside the junction box. See Fig. 7

Note: Carry out the power supplly con- nection in accordance with the natio- nal electric code, ANSI/NFPA 70-1999.

8.Secure cover to junction box using (2) screws.

Note1: A cable lock (not included) may be required by local codes. Please review local codes for more informa- tion.

9. Attach 6 pin male molex connectors to 6 pin fe- male molex connectors inside blower housing. See Fig. 8

Note2: Check local codes to determine minimum wire gauge.

See manual included with external and in-line blower for instructions on installing the blower.

Installation - External & In-Line Blower Preparation