READ AND SAVE THESE INSTRUCTIONS

Important safety Notice

CAUTION:

FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

B.Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

C.Installation Work and Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes & Standards, Including Fire-rated Construction.

D.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back- drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

E.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

F.Ducted systems must always be vented to the outdoors.

CAUTION:

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.

Install this hood in accordance with all requirements specified.

WARNING

To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Hood With Any External Solid State Speed Control Device.

WARNING

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.

a)Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b)Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).

c)Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d)Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:

a)SMOTHER FLAMES with a close-fitting lid, cookie sheet, or other metal tray, then turn off the gas burner or the electric element. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

b)NEVER PICK UP A FLAMING PAN - you may be burned.

c)DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

d)Use an extinguisher ONLY if:

1)You know you have a class ABC extinguisher, and you already know how to operate it.

2)The fire is small and contained in the area where it started.

3)The fire department is being called.

4)You can fight the fire with your back to an exit.

OPERATION

a. Always leave safety grills and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.

The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.

* NOTE: Please check our website for revisions before doing any custom work.

4

Page 4
Image 4
Zephyr EBO-E42ASX, EBO-E36ASX manual Important safety Notice, Operation

EBO-E42ASX, EBO-E36ASX specifications

The Zephyr EBO-E36ASX and EBO-E42ASX are advanced cooling solutions designed for commercial applications where energy efficiency, performance, and reliability are paramount. Both models offer superior features tailored for various industries, making them reliable choices for those seeking quality and durability in air conditioning technology.

One of the standout features of the EBO-E36ASX and EBO-E42ASX is their inverter-driven compressor technology. This innovation allows the units to adjust the compressor speed according to the cooling load, ensuring optimal performance while minimizing energy consumption. As a result, these models achieve higher Seasonal Energy Efficiency Ratios (SEER), significantly reducing electricity bills while also contributing to a more sustainable environment.

Both units are equipped with advanced air filtration systems. These systems incorporate multi-layer filters designed to capture airborne particulates, allergens, and pollutants. This feature not only enhances indoor air quality but also contributes to a healthier working environment, making the EBO models well-suited for offices, schools, and hospitals. The filters are easy to access and can be replaced or cleaned without hassle.

In terms of design, the EBO-E36ASX and EBO-E42ASX units come with compact dimensions, allowing for versatile installation options. They can be mounted in various orientations, fitting seamlessly into a range of architectural layouts. The exterior casing is crafted from durable materials, ensuring that the units withstand harsh weather conditions and maintain their aesthetic appeal over time.

Moreover, both models feature a quiet operation mode, a crucial aspect for environments where noise reduction is essential. Utilizing sound-dampening technologies, these units operate at low noise levels, contributing to a comfortable atmosphere in offices, restaurants, and homes.

Integration with smart home technologies is another remarkable characteristic of the EBO-E36ASX and EBO-E42ASX. They are compatible with various smart thermostats and can be controlled remotely through mobile applications. This feature enables users to monitor and adjust settings, ensuring optimal indoor comfort while maximizing energy efficiency.

Overall, Zephyr's EBO-E36ASX and EBO-E42ASX represent a blend of cutting-edge technology, efficient performance, and user-friendly design. Their commitment to energy efficiency, air quality, and quiet operation makes them exemplary options for those looking to enhance their indoor environments. With these models, Zephyr continues to push the boundaries of HVAC technology, ensuring comfort and sustainability in commercial and residential applications alike.