5. INSTALL THE ADAPTER/DAMPER (CONT’D)
VERTICAL DISCHARGE
For a vertical discharge installation only, leave the foldable flange (C) of the adapter/damper as is. This flange must be located towards the front of the hood.
See beside.
ALL INSTALLATIONS
Using two 1/2” screws, secure the adapter/damper to the top or back of the hood. Tape the adapter/damper to the hood using duct tape to seal it.
C
HO0096 |
HO0095 |
NOTES: 1. For the best ventilation performance, if a round duct must be used, the duct diameter must be 6” or more. Use a 3¼” x 10” to 6” round transition.
2.The wall duct must be well prepared to receive the adapter. Before performing the installation, make sure the adapter fits easily in the duct.
6.INSTALL THE HOOD
Run power cable to installation location. Place the hood at its location. Using a pen, mark the position of the screws (smaller part of the embossed keyholes). Remove the hood and install four 1/2” double thread screws at sides locations (A), leaving a 1/8” gap. Place the wire clamp, insert the cable in the hood and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the adapter/damper assembly enters the ducting and the damper opens freely. Secure the hood by tightening the screws completely. Install the last 1/2 double thread screw (B) in the remaining embossed hole.
HD0218 |