Zephyr ZGE-E30AS290, ZGE-E36AS290 manual Installation - Installing the Hood

Models: ZGE-E36AS290 ZGE-E36AS ZGE-E30AS290 ZGE-E30AS

1 49
Download 49 pages 43.37 Kb
Page 12
Image 12
Fig.3

Installation – Installing the Hood

www.zephyronline.com

Fig.4!Fig.5 WARNING: Electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring.

1) Prepare electrical wiring and ducting in cabinet. Location of junction box and blower outlet can be found on page 8.

Fig.3

Fig.4

2) Unscrew the (10) screws from front panel and place

3) Open cabinet doors. Lift range hood and slide it through

the panel aside, Fig.3. You will now have access to the

the opening located in the bottom of the cabinet, Fig.4.

interrior of the range hood.

Make sure opening matches the dimensions on page 9,

 

Fig.1.

2

1

Fig.5

4)There are spring clips located on the left and right sides of the hood body which will temporarily hold the hood in place, Fig.5.

Fig.6

5)Secure upper brackets to left and right sides of hood body by using (2) 3/16 x 3/8” screws for each bracket. Fig.6. Make sure the (2) captive nut screw holes on the bracket are facing downward. Note: Due to limited workspace in 30” cabinets you will need to use a right angle or 2” long Philips head screwdriver.

10

Page 12
Image 12