Installation – Mounting the Hood!Cable Lock CAUTION: At least two installers are required due to the weight and size of the hood.

1.Measure from range top to hood bottom and mark line A. (28” minimum from range top) .

2.Plum and mark center line.

3.Mark mounting height line B. (15-3/8” from line A)

4.Mark mounting spread from C/L. (8-7/8”)

5.Fasten (2) M4 x 1-1/2” screws into studs on line B but do not tighten all the way. Note: Wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also be used but check local codes before using wall anchors.

6.Remove the (2) metal mesh filters.

7.Remove the (2) charcoal filter brackets located inside the hoood behind the metal mesh filters. Each bracket is secured with (4) 3/16 x 6 Philips head screws. Note: If you are not recirculating the hood you may discard the charcoal brackets.

8.Hang hood onto the mounting screws and hand tighten each screw. (fig A) Secure third M4 x 1-1/2” screw through inside of hood into wall for extra support. (fig A2)

9.Center and attach duct cover mounting bracket to wall just below the ceiling or soffit using (2) M4 x 1” screws.

10.Install electrical and duct work. Seal duct work with aluminum duct tape.

11.Power up hood and check for leaks around duct tape.

12.Place telescopic duct covers onto hood and extend inner (top) duct cover upwards and secure to duct cover bracket using (2) M3.5 x 8 screws. Secure bottom duct cover to hood body by also using (2) M3.5 x 8 screws.

*If using hood in recirculating mode you must secure the air diverter plate onto wall before installing duct work and duct covers. Turn to page 10 for more details.

15-3/8

Brackets are pre-installed

fig. A

fig. A2

Installation – Mounting the Hood

Manual background!Manual background WARNING: Electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring.

Cable Lock

A cable locking connector (not supplied) might be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary.

Cable Lock