Important Safety Instructions

!Important Safety Instructions

1Read and follow all warning notices and instructions marked on the product or included in the manual.

2Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel.

3WARNING: This unit supports a redundant 48 VDC power input connection. Disconnect both sources of input power before servicing.

4This product is to be installed only in a Restricted Access Location (dedicated equipment rooms, equipment closets or the like) in accordance with articles 110-16, 110-17 and 110-18 of the National Electrical Code, ANSI/NFPA 70.

5This product is to be connected to a 48 VDC SELV supply source that is electrically isolated from the AC source.

6The positive terminal of the 48 VDC source is to be reliably connected to earth. Connect a green/yellow earthing (grounding) wire to the protective earthing (grounding) lug connector, identified by the protective earth symbol on the chassis.

7A readily accessible disconnect device as part of the building installation shall be incorporated in fixed wiring. The disconnect device (a 48 VDC, 10 A, single pole circuit breaker or switch) must be included in the ungrounded supply conductor. Over current protection must be included with a 48 VDC, 10 A fuse or circuit breaker in the ungrounded conductor. Use minimum 16 AWG (2.5 mm2) fixed power source wires with strain retention.

8Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord.

9Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.

10General purpose cables are described for use with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer. To reduce the risk of fire, use a UL Listed or CSA Certified, minimum No. 26 AWG (0.128 mm2) telecommunication cable, or comparable cables certified for use in the country of installation.

11A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.

12In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:

— Never install telephone wiring during a lightning storm.

IPD4-A2-ZZ40-20

4000E IP Broadband Loop Carrier Installation Instructions

19

Page 19
Image 19
Zhone Technologies 4000E installation instructions Important Safety Instructions

4000E specifications

Zhone Technologies has long been recognized as a leader in providing innovative and advanced networking solutions for telecommunications and internet service providers. Among its notable offerings, the Zhone 4000E series stands out as a versatile and robust platform designed to meet the demands of modern network environments. This article explores the main features, technologies, and characteristics of the Zhone 4000E.

One of the key features of the Zhone 4000E is its flexibility in deployment. This platform supports a range of access technologies, including xDSL, fiber, and Ethernet, making it suitable for various use cases, whether in urban or rural settings. The ability to support multiple access methods allows service providers to deliver high-speed internet and voice services to diverse customer demographics without the need for extensive hardware or infrastructure changes.

The Zhone 4000E is powered by a highly scalable architecture, enabling service providers to easily expand their network capacity as demand grows. This scalability is critical in an era where internet usage is continually increasing. Its modular design allows operators to add or upgrade components seamlessly, ensuring that their network can adapt to emerging technologies and growing traffic requirements.

In terms of performance, the Zhone 4000E excels with its advanced Quality of Service (QoS) capabilities. This feature prioritizes network traffic to ensure that real-time services such as voice over IP (VoIP) and video streaming receive the necessary bandwidth and low latency to function optimally. This capability is increasingly important as consumer expectations for service quality are higher than ever.

Another significant aspect of the Zhone 4000E is its robust security features. With built-in encryption and advanced firewalls, the platform ensures that both service providers and end-users can operate their networks with confidence. Security is a crucial concern in today’s digital landscape, and Zhone has made addressing this a priority in their product design.

Furthermore, the Zhone 4000E is equipped with comprehensive management tools that simplify network monitoring and troubleshooting. These tools provide real-time insights into network performance and can help identify potential issues before they affect customers. This proactive approach to management helps service providers maintain high levels of customer satisfaction and operational efficiency.

In summary, the Zhone 4000E series is a highly versatile and capable platform that combines flexibility, scalability, performance, security, and management efficiency. Its ability to adapt to various technologies and growing demands makes it an excellent choice for service providers looking to enhance their offerings and stay competitive in a fast-evolving digital market.