Step 1

Alignment Tools Level vs. RSSI :

 

RSSI (dBm)

Level

 

-90

0

(RSSI+90)*2

-4590

Alignment Tools vs. SNR :

 

Beep Frequency

SNR (dB)

 

 

0

SNR< =25

 

 

0.975Hz

25<SNR<=30

 

1.95Hz

30<SNR<=35

 

3.9Hz

35<SNR<=40

 

7.8Hz

40<SNR<=45

 

15.6Hz

45<SNR<=55

 

31.2Hz

55<SNR<=60

SNR>60

5.11.Special Notice for Waterproof Installation

Most problems of waterproof installation for the outdoor units are caused by the loose connections due to vibration or other forces, under this condition, it is possible for the moisture to penetrate into the main unit from the connector. The following procedures are recommendations for outdoor waterproof installation.

Step 1. Ensure that you already fasten all connectors tightly.

Step 2. Tightly wrap two layers of self-bonding insulating tape forward and backward over the physical connection (the tape from a good brand is recommended). Extending two inches beyond the connectors or beyond the end of heat-shrinkable tubing on the RF coaxial cable and overlapping the tape on each turn are also required for better waterproof installation.

Step 1

 

Step 2

 

 

 

RF coaxial

POE cable

cable

connection

connection

 

Figure 5-10 Waterproof installation of cable connections