3.3.The Indoor Unit

Figure 3-2 Top panel of outdoor unit

Figure 3-3 Bottom panel of outdoor unit

 

 

 

Table 3-1 Connectors of outdoor unit

 

 

 

 

 

 

Function

Location

Label

Interface

 

Description

Antenna

Top

 

N male RF connector with

Connecting to the outdoor antenna

 

 

 

special water proof

 

 

Signal &

Bottom

 

8-pin female connector

 

Connecting to the indoor interface unit

Power

 

 

with special water proof

supplying the power and signal

Antenna

Bottom

 

8-pin male connector with

Connecting to AK-100 for antenna

alignment

 

 

special water proof

 

alignment

3.3.The Indoor Unit

The indoor unit is a network/power injector which is used to combine the signal stream and DC power into single category-5 cable to connect outdoor unit. It has three ports.

Table 3-2 Connectors of indoor unit

Function

Name

Connector

Description

Power

POWER

Power jack

Connecting to the outdoor antenna

Ethernet

TO LAN

RJ45

User for CPE connection via straight through

 

 

 

Ethernet cable

Signal & Power

TO RADIO

RJ45

Used for outdoor unit connection via special

 

 

 

waterproof category-5 cable

4. Configuring A-6000

This guide shows you the default factory configuration of A-6000 and how to configure the A-6000 for appropriate operation at the first time. See the User’s Guide for configuration details.

4.1.Default Configuration

The A-6000 is shipped with following factory default configurations:

Table 4-1 Default configuration

 

BU

RU

LAN IP

192.168.1.1

192.168.1.1

Subnet Mask

255.255.255.0

255.255.255.0

Wireless ESSID

Wireless

Wireless

Username/Password

admin/1234

admin/1234

7