Chapter 19
Table 59 RMON History Statistics: Control (continued)
LABEL | DESCRIPTION |
Utilization (%) | This field displays the utilization as a percentage of maximum utilization allowed on |
| the port in this polling sample. |
|
|
History | Click this to go back to the RMON History Statistics: Overview screen. |
Statistics |
|
Overview |
|
|
|
19.5 RMON Alarm: Overview
Use the RMON Alarm: Overview screen to view configured alarms that occur when the sampled data exceeds the specified threshold. To open this screen select [3] Alarm in the RMON MIB Table: drop down list box in the
Figure 78 RMON Alarm: Overview.
The following table describes the labels in this screen.
Table 60 RMON Alarm: Overview
LABEL | DESCRIPTION |
RMON MIB | Use this drop down list box to select the MIB table you want to view. Click Apply to |
Table: | refresh the screen to the selected MIB table view. |
|
|
Refresh | Click this to update all the fields in the RMON Alarm: Overview screen. |
|
|
Create new | Click this to view the RMON Alarm: Create New Alarm screen where you can |
Alarm | configure the parameters for an alarm. |
|
|
Index | This field displays the alarm configuration index number. Click this number to edit |
| the alarm entry. |
|
|
Interval (sec) | This field displays the time interval (in seconds) between data samplings. |
|
|
Variable | This field displays the name of the MIB field whose data is to be sampled. |
|
|
Sample Type | This field displays the method of obtaining the sample value (absoluteValue or |
| deltaValue). |
|
|
Value | This field displays the value of the statistic during the last sampling period. This |
| value is for comparing against the RisingThreshold and FallingThreshold values. |
|
|
Startup Alarm | This field displays the alarm type (1:rising, 2:falling, or 3:risingOrFallingAlarm) |
| that can be sent when this alarm is first activated. |
|
|