TROUBLESHOOTING
| TROUBLE | CAUSE | WHAT TO DO | |||
|
|
|
|
|
|
|
| A. | Input contactor chatters. | 1. | Faulty input contactor. | 1. | Refer to wiring diagram & |
|
|
|
|
|
| check related leads. |
|
|
| 2. | Low line voltage. | 2. | Check input power. |
|
|
| 3. | Pilot transformer (T2) misconnected. | 3. | Check input connection instructions. |
|
|
|
|
|
| |
| B. Machine input contactor does | 1. | Supply line fuse blown. | 1. | Replace if | |
|
| not operate. |
|
|
|
|
|
|
| 2. | Contactor power circuit dead. | 2. | Check pilot transformer T2 and |
|
|
|
|
|
| associated leads. |
|
|
| 3. | Broken power lead. | 3. | Check input voltage at contactor. |
|
|
| 4. | Wrong input voltage. | 4. | Check voltage against instructions. |
|
|
| 5. | Primary thermostats open. | 5. | Check for overheating; make sure fan is |
|
|
|
|
|
| operating and there is no obstruction to free |
|
|
|
|
|
| air flow. Replaces faulty thermostat. |
|
|
| 6. | Open input contactor coil. | 6. | Replace coil. |
|
|
| 7. | Power ”On/Off” switch (S1) not | 7. | Replace switch. |
|
|
|
| closing. |
|
|
| C. | Machine input contactor | 1. | Electrode or work lead loose or | 1. | Repair connection. |
|
| operates, but no output when |
| broken. |
|
|
|
| trying to weld. |
|
|
|
|
|
|
| 2. | Open main transformer (T1) | 2. | Repair. |
|
|
|
| primary or secondary circuit. |
|
|
|
|
| 3. | Defective Control P.C. Boards. | 3. | Replace. See P.C. Board |
|
|
|
|
|
| Troubleshooting Procedure. |
|
|
| 4. | Output terminals switch set | 4. | Check setting/operation of the |
|
|
|
| wrong or faulty. |
| Output Terminals switch. |
|
|
| 5. | Secondary thermostat open. | 5. | Check for overheating; make sure fan is |
|
|
|
|
|
| operating and there is no obstruction to free |
|
|
|
|
|
| air flow. Replaces faulty thermostat. |
|
|
|
|
|
| |
| D. Machine has high output and | 1. | Fault in leads 75, 76, or 77. | 1. | Check wiring. | |
|
| no control. |
|
|
|
|
|
|
| 2. | Open in feedback circuity. | 2. | Check control and protection PC Baord |
|
|
|
|
|
| wiring. With input power off, check for |
|
|
|
|
|
| continuity between (+) output stud and lead |
|
|
|
|
|
| and 1J12 on the control board. Also check for |
|
|
|
|
|
| continuity between GMAW/FCAW |
|
|
|
|
|
| stud and 3J12 on the control board. Finally, |
|
|
|
|
|
| check for continuity between SMAW/SAW |
|
|
|
|
|
| output stud and 2J12. Repair if necessary. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.