Lincoln Electric IM463-A manual Trouble Cause What to do

Page 20

TROUBLESHOOTING

 

TROUBLE

CAUSE

WHAT TO DO

 

 

 

 

 

 

 

 

A.

Input contactor chatters.

1.

Faulty input contactor.

1.

Refer to wiring diagram &

 

 

 

 

 

 

check related leads.

 

 

 

2.

Low line voltage.

2.

Check input power.

 

 

 

3.

Pilot transformer (T2) misconnected.

3.

Check input connection instructions.

 

 

 

 

 

 

 

B. Machine input contactor does

1.

Supply line fuse blown.

1.

Replace if blown-look for reason first.

 

 

not operate.

 

 

 

 

 

 

 

2.

Contactor power circuit dead.

2.

Check pilot transformer T2 and

 

 

 

 

 

 

associated leads.

 

 

 

3.

Broken power lead.

3.

Check input voltage at contactor.

 

 

 

4.

Wrong input voltage.

4.

Check voltage against instructions.

 

 

 

5.

Primary thermostats open.

5.

Check for overheating; make sure fan is

 

 

 

 

 

 

operating and there is no obstruction to free

 

 

 

 

 

 

air flow. Replaces faulty thermostat.

 

 

 

6.

Open input contactor coil.

6.

Replace coil.

 

 

 

7.

Power ”On/Off” switch (S1) not

7.

Replace switch.

 

 

 

 

closing.

 

 

 

C.

Machine input contactor

1.

Electrode or work lead loose or

1.

Repair connection.

 

 

operates, but no output when

 

broken.

 

 

 

 

trying to weld.

 

 

 

 

 

 

 

2.

Open main transformer (T1)

2.

Repair.

 

 

 

 

primary or secondary circuit.

 

 

 

 

 

3.

Defective Control P.C. Boards.

3.

Replace. See P.C. Board

 

 

 

 

 

 

Troubleshooting Procedure.

 

 

 

4.

Output terminals switch set

4.

Check setting/operation of the

 

 

 

 

wrong or faulty.

 

Output Terminals switch.

 

 

 

5.

Secondary thermostat open.

5.

Check for overheating; make sure fan is

 

 

 

 

 

 

operating and there is no obstruction to free

 

 

 

 

 

 

air flow. Replaces faulty thermostat.

 

 

 

 

 

 

 

D. Machine has high output and

1.

Fault in leads 75, 76, or 77.

1.

Check wiring.

 

 

no control.

 

 

 

 

 

 

 

2.

Open in feedback circuity.

2.

Check control and protection PC Baord

 

 

 

 

 

 

wiring. With input power off, check for

 

 

 

 

 

 

continuity between (+) output stud and lead

 

 

 

 

 

 

and 1J12 on the control board. Also check for

 

 

 

 

 

 

continuity between GMAW/FCAW (-) output

 

 

 

 

 

 

stud and 3J12 on the control board. Finally,

 

 

 

 

 

 

check for continuity between SMAW/SAW (-)

 

 

 

 

 

 

output stud and 2J12. Repair if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

20

Image 20
Contents DC-650 PRO Electric Shock can kill ARC Welding can be hazardousCylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcTable of Contents Thank You Please Examine Carton and Equipment For Damage ImmediatelyTechnical Specifications Input SpecificationsOutput Specifications General DescriptionInstallation Minimizing Problems Due to High FrequencyElectric Shock can kill LocationPage Recommended Input Wire and Fuse Sizes Output Connections Wire Feeder Control Cable Connections DC-650 PROConnection of a K775 Remote Output Control Connection to Auxiliary PowerExplanation of Controls Mode Switch Wire Feeder Voltmeter SwitchOutput Terminals Switch Power Switch and Pilot LightMode Gmaw Control SwitchOperating Instructions Voltmeter Output Terminals RemoteMode Fcaw Mode SAWFcaw Flux-Cored Operation SAW Submerged Arc OperationOperation with an LN-9 or NA-5 Wire Feeder Smaw Stick OperationInstallation with an NA-3 Protective CircuitryAC-A Arc Gouging Operation Thermostatic ProtectionTroubleshooting Routine MaintenancePower Source Troubleshooting Overload ProtectionTrouble Cause What to do Check & replace if defective Troubleshooting Accessory Troubleshooting Gmaw modeTroubleshooting Page Meter PC Board Protection PC BoardSnubber PC Board Output Bypass PC BoardsDC-650 PRO Wiring Diagram Dimension Prints DC-650 PRO with a K817 Undercarriage DC-650 PRO DC-750 223Page How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? $700.00Precaucion Warnung